1. GENERAL INFORMATION

 

Dear customer, 

 

 

Thank you for purchasing our product. In the following, we will show you 

which things should be noted during the use. 

 

 

Should  you  encounter  any  unexpected  problems,  do  not  hesitate  to 

contact us. 

 

This case is made for an additional power supply which allows 

you to connect this lab power supply directly to alternating 

current. 

 

 

Therefore, this safety instruction is necessary: 

 

 

 

For your own safety, this product may only be 

 

installed by a qualified electrician! Working on 

 

electric devices / systems implies the hazard of 

 

electric shocks which may cause serious injuries or 

even death! 

 

!

 

Summary of Contents for JT-RD6012-Case1

Page 1: ... encounter any unexpected problems do not hesitate to contact us This case is made for an additional power supply which allows you to connect this lab power supply directly to alternating current Therefore this safety instruction is necessary For your own safety this product may only be installed by a qualified electrician Working on electric devices systems implies the hazard of electric shocks w...

Page 2: ...he on and off switch which gets plugged in and the power connector which gets screwed in with the small silver screws 3 Now you can attach the extension of the temperature sensor to get the temperature sensor outside of the case You can also mount without these if required which allows you to use an internal instead of an external temperature sensor ...

Page 3: ...ascalstr 8 47506 Neukirchen Vluyn 4 If available insert the WiFi module in the RD6012 5 Now insert the RD6012 into the case 6 Place the power supply unit into the case as shown in the picture and screw it on from below ...

Page 4: ...itch with the short brown cable phase The yellow green cable grounding goes directly from the power plug to the power supply unit where it is connected to the connector which is marked as ground symbol The lowest connection is led directly to the power supply unit with the blue cable neutral conductor and is connec ted to N The other connector of the switch is connected with the long brown cable t...

Page 5: ...6012 has an input voltage of 65 V so that the full 60 V of output voltage can be realised Note the switch on the side of the power supply with which you can set the input voltage This means that if you have an input voltage of 90 to 132 V AC slide the switch to 115 V left and if you have an input voltage of 180 to 264 V AC slide the switch to 230 V right ...

Page 6: ...ternal temperature sensor and the temperature sensor from the outside at the extension or you can connect the temperature sensor directly to the RD6012 so that it is inside the case 9 Now we connect the RD6012 to the power supply We connect IN with the red cable to V and IN with black cable to COM ...

Page 7: ...www joy it net Pascalstr 8 47506 Neukirchen Vluyn 11 Now fix the cover with the eight screws and your RD6012 is ready to use ...

Page 8: ...ew product in normal household quantities 1 Possibility of return at our company location during our opening hours Simac Electronics Handel GmbH Pascalstr 8 D 47506 Neukirchen Vluyn 2 Possibility of return nearby We will send you a parcel stamp with which you can send us your old appliance free of charge For this possibility please contact us via e mail at service joy it net or via telephone Infor...