Instruction Manual
43
Example of a GET returned data
0 0 0 10000 0 0 10000 2 1009 M 30 0 2 1 1 1 0 0 0 1 11.5 80 D4FD
Explanation:
Sensor ID = 0
User Alarm 1 not set
User Alarm 1 not active
User Alarm 1 distance = 10000 metres
User Alarm 2 not set
User Alarm 2 not active
User Alarm 2 distance = 10000 metres
Serial baud rate 2 (=38400Bd)
Serial number = 1009
Visibility Units = M
Continuous mode output interval = 30 seconds
Polling mode = 0 (continuous mode)
Message format = 2 (full message)
RS-232 or RS-485 serial communications = 1 ( RS-485)
Averaging period = 1 minute
Sample timing = 1 sample per second
Dew heater override = 0 (sensor will automatically control the dew heaters)
Hood heater override = 0 (sensor will automatically control the hood heaters)
Dirty window compensation = 0 (dirty window compensation off)
CRC-16 checking on received commands = 1 (CRC-16 checking enabled)
Sensor power down voltage = 11.5V
Relative humidity threshold 80 (CS125 only)
Checksum = D4FD