![Campbell CS120A Instruction Manual Download Page 51](http://html1.mh-extra.com/html/campbell/cs120a/cs120a_instruction-manual_488900051.webp)
Instruction Manual
39
14.2.1 Example of a SETNC Command
14.3 The MSGSET Command
The user customisable message format can be configured using the MSGSET
command.
When a valid MSGSET command is issued a MSGGET response comes back
from the sensor.
Example
Bit
Description
0x01
(Hex)
-
SOH
:
-
Delimiting character
MSGSET
-
MSG SET
:
-
Delimiting character
0
-
Sensor ID
:
-
Delimiting character
The following represent 16 bits of a hex value
16
Reserved
15
Reserved
14
Humidity (%)
(1) (2)
13
Temperature (Degrees C)
(1)
12
NWS code
(1)
11
METAR code
(1)
10
SYNOP code
(1)
9
Generic SYNOP
(1)
8
Accumulation
(1)
7
Intensity
(1)
6
Particle count
(1)
5
Sensor serial number
4
Dirty windows values
3
System alarms
2
User alarms
1
Averaging duration
:
Delimiting character
XXXX
Checksum
:
Delimiting character
0x04
(Hex)
EOT
These selections output more than one variable
(1)
These options will only be available if you’re using a CS125
(2)
Only outputs a valid final message value when a CS215 temperature and humidity probe is connected
Description of the custom message bits
Bit
Description
8000
Reserved
4000
Reserved
2000
Humidity (%)
1000
Temperature (Degrees C)
SETNC:0:0 1 1 1000 1 0 15000 2 0 M 60 1 2 0 1 1 0 0 0 1 7 80 :XXXX:
Summary of Contents for CS120A
Page 2: ...ii ...
Page 4: ......
Page 6: ......
Page 8: ......
Page 12: ...vi ...
Page 73: ...A 1 Appendix A CS120A CS125 block diagram ...
Page 74: ...CS120A and CS125 Visibility and Present Weather Sensors A 2 ...
Page 76: ...CS120A and CS125 Visibility and Present Weather Sensors B 2 ...
Page 90: ......