Serial port settings can be configured using the ALERT2 IND API or by using the AL205E
configuration menu. The AL205E implements version 1.0 of the ALERT2 IND API. Default serial
port settings are the following:
Table 7-2: Default serial port settings
Setting name
Setting value
Input Mode
API
Output Mode
API
Baud Rate
9600
Parity
None
Stop Bits
1
Flow Control
None
Independent Addressing
False/Off
Address
9000 (not enabled by default)
(p. 23) provides the pinout for the TX port.
Table 7-3: TX pinout (from left, facing the AL205E)
Pin number
Label
Pin function
1
AO
RF data (output from the AL205E)
2
G
Ground
3
PTT
Push to talk
4
12V
12 V power (provided by the AL205E)
5
CS
Channel select
7.1 Radio output level
On the circuit board, the AL205E has two jumpers that enable user-customization of the audio
level sent to the TX radio. Different radios have different audio voltage level requirements.
Fixed settings are provided for the commonly used Ritron and Maxon radios, while a third setting
allows user customization with an adjustable potentiometer. Refer to your radio specifications for
the proper input voltage level.