Table 4-5: Example message components
Prefix
Length
API command
(type)
Length
Value
ASCII/
Decimal
ALERT2
10
Self-reporting
protocol
20
Payload
Encoded
Hex
41 4C 45 52 54 32
0A
00
14
12 2C 07 01
0F 09 11 00
14 34 41 5C
7C 11 0C 34
42 AC DC BA
If a serial port is configured for ALERT concentration, it will not respond to API commands.
Instead, it is expecting binary ALERT-data in the 4-byte format as shown in the following table.
Table 4-6: ALERT concentration example
Prefix
Value
ASCII/ Decimal
3067
1022
Encoded Hex
7B 6F
FC DF
5. Test transmission procedure
The AL205E can generate test tones for radio and antenna testing. Use the following procedure
to generate test tones.
1. Connect the AL205E to the computer using a USB cable.
2. Start the Device Configuration Utility.
AL205E ALERT2 Encoder