Table 3-4: Serial 2 settings
1
Setting
number
Setting
Description
[15/55]
Port 1 type
Sets the type of information that is received on this serial
port.
0 (default) = ALERT API commands
1= ALERT (ALERT1) data that converts the data to a ALERT
concentration packet
[16/55]
Port 1 Independent
SA enabled?
When enabled, an independent source address is assigned to
this port.
0 (default) = disable
1 = enable
[17/55]
Port 1 source
address
Port 1 (serial port 2) is not configured for an independent
source address (SA). Therefore, an SA entry is not allowed.
The AL205E uses this port to send the IND address assigned
to the data. Range is 1 to 65534; default is 9001.
[18/55]
Port 1 baud
Baud rate setting for port 1 (Serial port 2). Valid entries are
57600 (default), 38400, 19200, 9600, 4800, or 1200.
[19/55]
Port 1 parity
0 (default) = none
1 = odd
2 = even
[20/55]
Port 1 stop bits
Valid entries are 1 (default) or 2.
1
Serial port 1 is labeled Serial 2 on the AL205E case.
AL205E ALERT2 Encoder
9