background image

4

Operating Instructions

www.chpower.com

Important Safety Instructions 
(Continued) 

 

Clean and check all 

  air supply hoses 

and fi ttings before connecting the 
tool to an air supply. Replace any 
damaged or worn hoses or fi ttings. 
Tool performance or durability may be 
reduced.

SERVICE

a.  

Tool service must be performed only 
by qualified repair personnel. 

b.  

When servicing a tool, use only 
identical replacement parts. Use 
only authorized parts. 

c.   

Use only the lubricants supplied 
with the tool or specified by the 
manufacturer. 

 

Do not make any 

 modifi cations to 

the tool without fi rst obtaining written 
approval from Campbell Hausfeld. Do 
not use the tool if any shields or guards 
are removed or altered. Do not use the 
tool as a hammer. Personal injury or 
tool damage may occur.

 Disconnect 

air 

  supply and release 

tension from the pusher before 
attempting to clear jams because 
fasteners can be ejected from the front 
of the tool. Personal injury may occur.

AIR SOURCE

a.  

Never connect to an air source that 
is capable of exceeding 200 psi. 

Over pressurizing the tool is able 
to result in bursting, abnormal 

operation, breakage of the tool or 
serious injury to persons. Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool. Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range. 

b.  

Never use oxygen, carbon dioxide, 
combustible gases or any bottled 
gas as an air source for the tool. 

Such gases are capable of explosion 
and serious injury to persons. 

Do not use any type of 
reactive gases, including, but 
not limited to, oxygen and 
combustible gases, as a power source. 
Use fi ltered, lubricated, regulated 
compressed air only. Use of a reactive 
gas instead of compressed air may 
cause the tool to explode which will 
cause death or serious personal injury.

Use only a pressure-regulated 
compressed air source to limit 
the air pressure supplied to 
the tool. The regulated pressure must 
not exceed 100 psi. If the regulator 
fails, the pressure delivered to the 
tool must not exceed 200 psi. The tool 
could explode which will cause death or 
serious personal injury.

SAVE THESE INSTRUCTIONS

DO NOT DISCARD 

OPERATING INSTRUCTIONS

 LUBRICATION

This tool requires lubrication before 
using the tool for the first time and 
before each use. If an inline oiler is 
used, manual lubrication through the 
air inlet 

is not

 required on a daily basis.

 

The work surface  

 can become 

damaged by excessive lubrication. 
Proper lubrication is the owner’s 
responsibility. Failure to lubricate the 
tool properly will dramatically shorten 
the life of the tool and void your 
warranty.

1.   Disconnect the air 

supply from the tool 
to add lubricant. 

2.   Turn the tool so the 

air inlet is facing up. Place 
4-5 drops of 30 W non-
detergent oil into air inlet. 
Do not use detergent oils, 
oil additives, or air- tool 
oils. Air tool oils contain solvents 
which will damage the tool’s 
internal components. 

3.   After adding oil, run 

tool briefly. Wipe off 
any excess oil from 
the cap exhaust.

 Recommended Hookup

Quick Plug

Quick 
Coupler

Air Hose

Quick Plug 
(Optional)

Quick 
Coupler 
(Optional)

Regulator

Lubricator

Filter

OIL

OIL

O

CO

2

100 psi

Summary of Contents for IronForce IFN328K0

Page 1: ...his information observe the following symbols Danger indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous s...

Page 2: ...unintentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on d Do n...

Page 3: ...ct the tool from the air source before making any adjustments changing accessories or storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally e Store the...

Page 4: ...ce for the tool Such gases are capable of explosion and serious injury to persons Do not use any type of reactive gases including but not limited to oxygen and combustible gases as a power source Use...

Page 5: ...m before each use The WCE must move freely without binding through its entire travel distance The WCE spring must return the WCE to its fully extended position after being depressed Do not operate the...

Page 6: ...screwdriver if required 6 Rotate door back into the closed position 7 Extend the wire latch and place over the hooks on the nose 8 Close the latch by pushing the latch up and in until the latch snaps...

Page 7: ...Gauge 1 4 Chisel Galvanized Vinyl Coated Adhesive 100 5000 FN258K00 1 18 Gauge 1 4 Chisel Galvanized Vinyl Coated Adhesive 100 5000 FN180615AV 1 2 18 Gauge 1 4 Chisel Galvanized Vinyl Coated Adhesive...

Page 8: ...on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Stapler runs slow or has loss of power 1 Stapler not lubricated sufficiently 1 Lubric...

Page 9: ...9 IFN328K0 www chpower com Notes...

Page 10: ...h product Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices ar...

Page 11: ...uation hasardeuse imminente qui R SULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessures graves Attention...

Page 12: ...urer que l interrupteur est en position d arr t off avant de brancher l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air avec l i...

Page 13: ...Ne toucher la g chette qu au moment de poser des attaches Ne jamais actionner la g chette durant le transport de l outil ou durant le raccordement de celle ci au tuyau d air comprim L jection accident...

Page 14: ...vant d utiliser l outil que la source d air est ajust e la pression d air nominale ou dans la plage de pression d air nominale b Ne jamais utiliser d oxyg ne de dioxyde de carbone de gaz combustible o...

Page 15: ...L UNIQUE La g chette doit tre tir e chaque fois qu une attache est enfonc e L outil peut tre actionn e en pla ant le m canisme de d clenchement pointe de contact WCE contre la surface de travail et en...

Page 16: ...lenchement par contact WCE peut s effectuer vers le haut ou vers le bas sans difficult CHARGEMENT D CHARGEMENT DE L OUTIL 1 Toujours brancher l outil la source d air avant le chargement des attaches 2...

Page 17: ...ATTACHES ET R PARATION DE L OUTIL Seul un personnel qualifi doit r parer l outil en utilisant seulement des accessoires et des pi ces de rechange d origine ou des pi ces et accessoires qui fonctionne...

Page 18: ...l Galvanis Enduit de Vinyle Adh sive 100 5000 FN258K00 1 po 18 1 4 po Chisel Galvanis Enduit de Vinyle Adh sive 100 5000 FN180615AV 1 2 po 18 1 4 po Chisel Galvanis Enduit de Vinyle Adh sive 100 1000...

Page 19: ...ion 6 Remplacer les joints torique Graisser 7 Joint torique de la soupape de g chette endommag 7 Remplacer les joints torique 8 Fuites d air 8 Serrer les vis et raccords 9 Fuite du joint tanch it du c...

Page 20: ...on abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces ap...

Page 21: ...nte que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes s mbolos sto le indica que hay una situaci n...

Page 22: ...MUERTE o en LESIONES GRAVES REA DE TRABAJO a Mantenga el rea de trabajo limpia y bien iluminada Los bancos desordenados y las reas oscuras aumentan el riesgo de choque el ctrico incendio y lesiones p...

Page 23: ...gasolina o ning n otro l quido inflamable Nunca use la herramienta en la cercan as de l quidos o gases inflamables Una chispa podr a encender los vapores y ocasionar una explosi n que podr a ocasiona...

Page 24: ...parador antes de tratar de sacar cualquier sujetador atascado ya que la herramienta podr a disparar un sujetador por el frente sto podr a ocasionarle heridas SUMINISTRO DE AIRE a Nunca conecte a un su...

Page 25: ...r r pido de 9 5mm 3 8 con roscas de 6 4mm 1 4 NPT cuyo di metro interno sea de 8mm 0 315 y un acoplador r pido de 9 5mm 3 8 a la manguera de aire 4 Use un regulador de presi n de 0 bar 8 62 bar en el...

Page 26: ...a la presi n de 6 90 bar 2 Para dirigir el calador de sujetadores gire la rueda C hacia la derecha hasta el punto deseado 3 Para clavar el sujetador m s profundo gire la rueda C hacia la izquierda has...

Page 27: ...r ser reparada nicamente por personal calificado y deber n usar piezas de repuesto y accesorios originales Campbell Hausfeld o piezas y accesorios que funcionen de manera equivalente 27 Sp IFN328K0 PA...

Page 28: ...158K00 12 7 mm 1 2 Calibre 18 6 4mm 1 4 Cincel Galvanizado Cubierta por vinilo Adhesivo 100 5000 FN168K00 15 9 mm 5 8 Calibre 18 6 4mm 1 4 Cincel Galvanizado Cubierta por vinilo Adhesivo 100 5000 FN20...

Page 29: ...s anillos en O de la v lvula del gatillo est n da ados 7 Debe reemplazar los anillos en O 8 Hay fugas de aire 8 Debe apretar los tornillos y las conexiones 9 Hay una fuga en el empaque de la tapa 9 Re...

Page 30: ...manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a canc...

Page 31: ...Notes Notas IFN328K0 31...

Page 32: ...Notes Notas Operating Instructions Manual de Instrucciones de Operaci n Manuel d utilisation 32...

Reviews: