background image

4

Operating Instructions

 

PN001000

www.chpower.com

Important Safety Instructions 

(Continued) 

SERvICE

a.   Tool service must be performed only 

by qualified repair personnel. 

b.   When servicing a tool, use only 

identical replacement parts. Use 
only authorized parts. 

c.    Use only the lubricants supplied 

with the tool or specified by the 
manufacturer. 

 

Do not make any  

  modifications to 

the tool without first obtaining written 
approval from Campbell Hausfeld. Do 
not use the tool if any shields or guards 
are removed or altered. Do not use the 
tool as a hammer. Personal injury or 
tool damage may occur.

AIR SOURCE

a.   Never connect to an air source that 

is capable of exceeding 200 psi. 
Over pressurizing the tool is able 
to result in bursting, abnormal 
operation, breakage of the tool or 
serious injury to persons. Use only 
clean, dry, regulated compressed air 
at the rated pressure or within the 
rated pressure range as marked on 
the tool. Always verify prior to using 
the tool that the air source has been 
adjusted to the rated air pressure or 
within the rated air-pressure range. 

b.   Never use oxygen, carbon dioxide, 

combustible gases or any bottled 
gas as an air source for the tool. 
Such gases are capable of explosion 
and serious injury to persons. 

 

 

Do not use any type of 
reactive gases, including, but 
not limited to, oxygen and 
combustible gases, as a power source. 
Use filtered, lubricated, regulated 
compressed air only. Use of a reactive 
gas instead of compressed air may 
cause the tool to explode which will 
cause death or serious personal injury.
 

 

Use only a pressure-regulated 
compressed air source to limit 
the air pressure supplied to 
the tool. The regulated pressure must 
not exceed 125 psi. If the regulator 
fails, the pressure delivered to the 
tool must not exceed 200 psi. The tool 
could explode which will cause death or 
serious personal injury.

SAvE THESE INSTRUCTIONS 

DO NOT DISCARD

Operating Instructions

LUbRICATION

This tool requires lubrication before 
using the tool for the first time and 
before each use. If an inline oiler is 
used, manual lubrication through the 
air inlet 

is not

 required on a daily basis.

 

The work surface  

  can become 

damaged by excessive lubrication. 
Proper lubrication is the owner’s 
responsibility. Failure to lubricate the 
tool properly will dramatically shorten 
the life of the tool and void your 
warranty.

1.   Disconnect the 

air supply from 
the tool to 
add lubricant. 

2.   Turn the tool so the 

air inlet is facing up. 
Place 4-5 drops of 30 
W non-detergent oil 
into air inlet. Do not 

use detergent oils, oil additives, or 
air- tool oils. Air tool oils contain 
solvents which will damage the 
tool's internal components. 

3.   After adding oil, run 

tool briefly. Wipe off 
any excess oil from 
the cap exhaust.

RECOMMENDED HOOKUP

The illustration below shows the 
recommended hookup for the tool.
1.   The air compressor 

must be able to 
maintain a minimum 
of 50 psi when the 
tool is being used. An inadequate air 
supply can cause a loss of power and 
inconsistent driving.

2.   An oiler can be 

used to provide oil 
circulation through 
the tool. A filter can 
be used to remove 
liquid and solid impurities which can 
rust or “gum up” internal parts of 
the tool. 

3.   Always use air supply hoses with 

a minimum working pressure 
rating equal to or greater than the 
pressure from the power source if a 
regulator fails, or 150 psi, whichever 
is greater. Use 1/4 inch air hose for 
runs up to 50 feet. Use 3/8 inch or 
greater air hoses for 50 foot run or 
longer.

4.   Use a pressure regulator on the 

compressor, with an operating 
pressure of 0 psi - 125 psi. A pressure 
regulator is required to control 
the operating pressure of the tool 
between 50 psi and 125 psi. 

OIL

O

CO

2

125 psi

150 psi or greater

50 psi 

Min.
125 psi 

Max.

Minimum Recommended Hookup

Quick Plug

Quick 

Coupler

Air Hose

Quick Plug

Quick 

Coupler

Summary of Contents for IN730800AV

Page 1: ...etc before putting unit into service Safety Guidelines This manual contains information that is very important to know and understand This information is provided for SAFETY and to PREVENT EQUIPMENT P...

Page 2: ...lways assume that the tool contains fasteners Do not point the tool toward yourself or anyone whether it contains fasteners or not j Do not nail on top of another nail This is able to cause the nail t...

Page 3: ...the risk of injury to persons e Store the tool when it is idle out of reach of children and other untrained persons A tool is dangerous in the hands of untrained users f Maintain the tool with care K...

Page 4: ...h will cause death or serious personal injury Save These Instructions Do Not Discard Operating Instructions Lubrication This tool requires lubrication before using the tool for the first time and befo...

Page 5: ...epairing a tool the internal parts must be cleaned and lubricated Parker O lube or equivalent must be used on all o rings Each o ring must be coated with O lube before assembling A small amount of oil...

Page 6: ...lect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is vo...

Page 7: ...t de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher les symboles suivants pour cette information Danger indique une situation dangereu...

Page 8: ...e d quilibre si le boyau se d place i Toujours assumer que l outil contient des attaches Ne pas pointer l outil vers soi ou vers quelqu un d autre qu il y ait des attaches ou non j Ne pas clouer sur l...

Page 9: ...tandis que la cloueuse est charg e car cela pourrait mener la r initialisation imm diate de la soupape menant l jection du clou D abord raccorder la conduite d air puis charger d D brancher l outil d...

Page 10: ...t tre endommag e par le graissage excessif Le graissage correct est la responsabilit de l utilisateur Manque de graisser l outil correctement peut raccourcir la dur e de l outil et peut annuler votre...

Page 11: ...ettoy es et graiss es pendant la r paration d un outil Utiliser le Parker O lube ou l quivalent sur tous les joints toriques Chaque joint torique doit tre enrob avec du O lube avant l assemblage Utili...

Page 12: ...onctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s ret sont enlev s ou modifi s la garantie sera annu...

Page 13: ...nual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos como medida de SEGURIDAD y para EVITAR PROBLEMAS CON EL EQUIPO Debe reconocer los siguientes s...

Page 14: ...Adjunte la manguera a la estructura para reducir el riesgo de p rdida de equilibrio si la manguera se cambia de posici n i Siempre asuma que la herramienta contiene clavos No apunte con la herramienta...

Page 15: ...flamables Una chispa podr a encender los vapores y ocasionar una explosi n que podr a ocasionarle la muerte o heridas graves No quite modifique ni cause de otro modo que la traba del gatillo deje de f...

Page 16: ...gulador falla la presi n transmitida a la herramienta no debe exceder los 13 79 bar La herramienta puede explotar lo cual puede ocasionar la muerte o graves lesiones personales GUARDE ESTAS INSTRUCCIO...

Page 17: ...funcionen de manera equivalente Para colocarle los sellos Cada vez que repare una herramienta deber limpiarle y lubricarle las partes internas Le recomendamos que use Parker O lube o un lubricante eq...

Page 18: ...ir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los manua...

Page 19: ...19 Operating Instructions l Instructions d Utilisation l Manual de Instrucciones de Operaci n PN001000 Notes Notes Notas...

Page 20: ...20 Operating Instructions l Instructions d Utilisation l Manual de Instrucciones de Operaci n PN001000 Notes Notes Notas...

Reviews: