background image

Description

Portable oilless air compressors are for 
home and workshop use. Cleaning or 
replacement of the inlet filter on all 
models and draining moisture from the 
air receivers are required maintenance. 

Safety Guidelines

This manual contains information 
that is very important to know 
and understand. This information 
is provided for SAFETY and to 
PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger indicates 

  an imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 

Warning indicates 

  a potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates 

  a potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates 

  important 

information, that if not followed, may 
cause damage to equipment.

Unpacking

When unpacking unit, inspect carefully 
for any damage that may have occurred 
during transit. Make sure any loose 
fittings, bolts, etc., are tightened before 
putting unit into service. In case of 
questions, damaged or missing parts, 
please call 1-800-543-6400 for customer 
assistance. Have the serial number, 
model number, and parts list (with 
missing parts circled) before calling.

Do not retUrn  
the proDUct to  
the retailer!

 

Do not operate unit  

  if damaged during 

shipping, handling or use. Damage may 
result in bursting and cause injury or 
property damage.

reaD & Follow all inStrUctionS

Save theSe inStrUctionS

Do not DiScarD

STOP!

200 pSi portable aSMe 

air compressors

Breathable Air Warning

this compressor / pump is not 
equipped and should not be 
used “as is” to supply breathing 
quality air. For any application of 
air for human consumption, the 
air compressor / pump will need 
to be fitted with suitable in-line 
safety and alarm equipment. 
this additional equipment is 
necessary to properly filter 
and purify the air to meet 
minimal specifications for Grade 
D breathing  as described in 
compressed Gas association 
commodity Specification G 
7.1 - 1966, oSha 29 cFr 1910. 
134, and / or canadian Standards 
associations (cSa).

DiSclaiMer oF warrantieS
in the event the compressor is 
used for the purpose of breathing 
air application and proper in-line 
safety and alarm equipment is 
not simultaneously used, existing 
warranties shall be voided, and 
the campbell hausfeld disclaims 
any liability whatsoever for any 
loss, personal injury or damage.

Record the Model No., Serial No. and 
date of purchase in the space below.
Model No.  ______________________
Serial No. 

______________________

Date of purchase  _________________

Retain these numbers for future 

reference.

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

See warranty on page 8 for important information about commercial use of this product.

operating instructions 

hG3000 Series, hJ3001 Series, hJ3002 Series

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

IN634100AV 7/10

© 2010 Campbell Hausfeld/Scott Fetzer

For parts, product & service information, 

visit 

www.chpower.com

Summary of Contents for HJ3001 Series

Page 1: ...s compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suit...

Page 2: ...ay allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmfu...

Page 3: ...the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufac...

Page 4: ...essor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve i...

Page 5: ...hether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 12...

Page 6: ...alve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Proc...

Page 7: ...en compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check...

Page 8: ...sure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified...

Page 9: ...pas quip pour et ne devrait pas tre utilis comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est n cessaire d quiper le compresseur d air pompe av...

Page 10: ...out signe de faiblesse ou d usure et assurer que tous les raccordements sont s rs ne pas utiliser si endommag Contacter un centre de service autoris pour l inspection ou la r paration Ne Pas faire fon...

Page 11: ...s inflammables 3 Utiliser un respirateur pendant la pulv risation 4 Ne pas diriger la peinture ou autre mat riel pulv ris vers le compresseur Situer le compresseur aussi loin que possible de l endroit...

Page 12: ...r servoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de mani re appropri e Ce manom tre indique la pression maximum du compresseu...

Page 13: ...ant vert l ext rieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune une borne lectris Co...

Page 14: ...pression de sortie d passant la pression maximale indiqu e de l accessoire Cycle marche arr t du compresseur En position ON marche le compresseur pompe de l air dans le r servoir Lorsqu il atteint un...

Page 15: ...oteur du r servoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut v rifier et nettoyer p riodiquement le filtre air dans le bo tier du filtre du c t de la t te...

Page 16: ...ibre dans la section de Installation 3 Clapet ou d chargeur d fectueux 3 Remplacer ou r parer Le protecteur de surcharge thermique se d clenche souvant 1 Tension basse 1 V rifier avec un voltm tre 2 F...

Page 17: ...17 Fr S rie HG3000 S rie HJ3001 S rie HJ3002 Notes...

Page 18: ...tallation de fils incorrecte g Autres articles pas indiqu s mais consid r s pi ces fatigue g n rales h Manostats r gulateurs d air et soupapes de s ret qui ont t s modifi s d apr s les r glages de l u...

Page 19: ...e compra con fecha para fines de la garant a Adj ntela a este manual o arch vela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Port tiles ASME de 13 79 bar Po...

Page 20: ...ver si est n deterioradas o hay fugas Antes de usarlo cerci rese de que las conecciones est n bien apretadas y no lo use si encuentra irregularidades Notif quele a un centro de servicio autorizado par...

Reviews: