troubleshooting chart

Symptom

possible cause(s)

corrective action

Compressor will not 

run

1. Loss of power or overheating

1. Check for proper use of extension cord (see EXTENSION CORDS, 

page 5)

2. No electrical power

2. Plugged in? Check fuse/breaker or motor overload

3. Blown fuse

3. Replace blown fuse in household circuit

4. Breaker open

4. Reset, determining why problem happened

5. Thermal overload open

5. Motor will restart when cool; turn off compressor and wait 20 

minutes.

6. Pressure switch bad

6. Replace

Motor hums but 

cannot run or runs 

slowly

1. Low voltage

1. Check with voltmeter

2. Wrong gauge wire or length of 

extension cord

2. Check gauge chart, under Installation for proper gauge wire and 

cord length

3. Shorted or open motor winding

3. Replace motor

4. Defective check valve or unloader

4. Replace or repair

Fuses blow/circuit 

breaker trips 

repeatedly

1. Incorrect size fuse, circuit overloaded

1. Check for proper fuse, use time-delay fuse. Disconnect other 

electrical appliances from circuit or operate compressor on its 

own branch circuit

2. Wrong gauge wire or length of 

extension cord

2. Check gauge chart, under Installation

3. Defective check valve or under loader

3. Replace or repair

Thermal overload 

protector cuts out 

repeatedly

1. Low voltage

1. Check with voltmeter

2. Clogged air filter

2. Clean filter (see Maintenance section)

3. Lack of proper ventilation/room 

temperature too high

3. Move compressor to well ventilated area

4. Wrong gauge wire or length of 

extension cord

4. Check gauge chart, under Installation

Air receiver pressure 

drops when 

compressor shuts off

1. Loose connections (fittings, tubing, 

etc.)

1. Check all connections with soap and water solution and tighten

2. Loose drain lock

2. Tighten

3. Check valve leaking

3. Disassemble check valve assembly, clean or replace

 

Do not disassemble check valve  

  with air in tank; bleed tank first.

Excessive moisture in 

discharge air

1. Excessive water in air receiver

1. Drain receiver

2. High humidity

2. Move to area of less humidity; use air line filter

Compressor runs 

continuously

1. Defective pressure switch

1. Replace switch

2. Excessive air usage

2. Decrease air usage; compressor not large enough for a 

requirement

3. Check valve leaking

3. Disassemble check valve assembly, clean or replace

Compressor vibrates

Loose mounting bolts

Tighten

Air output lower 

than normal

1. Broken inlet valves

1. Have authorized service representative repair unit

2. Intake filter dirty

2. Clean or replace intake filter

3. Connections leaking

3. Tighten connections

Maintenance 

(continued)

 

This compressor is  

  equipped with a 

manual reset thermal overload protector 
which will shut off motor if it becomes 
overheated.

If thermal overload protector shuts 
motor off frequently look for the 
following causes.
 1.  Low voltage.

 2.  Wrong gauge wire or length of 

extension cord.

 3.  Clogged air filter.
 4.  Lack of proper ventilation.

 

The motor must be  

  allowed to cool down 

before start-up is possible. The motor will 
automatically restart without warning if 
left plugged into electrical outlet, if the 
motor is turned on.

StoraGe

 1.  When not in use, hose and 

compressor should be stored in a 
cool dry place.

 2.  Tank should be drained of moisture.
 3.  Hose should be disconnected and 

hung open ends down to allow any 
moisture to drain.

7

hG3000 Series, hJ3001 Series, hJ3002 Series

www.chpower.com

Summary of Contents for HG3000 Series

Page 1: ...is compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suitable in line safety and alarm equipment This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Ga...

Page 2: ...may allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmful Keep fingers away from a running compressor fast moving and hot parts will cause injury and or burns Disconnect power and depressurize system before servicing air compressor 9 Follow all local elec...

Page 3: ... the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer 6 Do not smoke when spraying paint insecticides or other flammable substances 7 Use a face mask respirator when spraying and spray in a well ventilated area to prevent health and fire hazards 8...

Page 4: ...ressor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve is located underneath the tank Use this valve to drain moisture from the tank daily to reduce the risk of corrosion Drain liquid from tank daily Reduce tank pressure below 10 psi then drain moisture f...

Page 5: ...whether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in Figure 4 Only connect the product to an outlet having the same configuration as the plug Do not use an adapter with this product...

Page 6: ...Valve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Procedure 2 Wearing safety glasses pull the ring on the safety valve see Figure 5 to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your f...

Page 7: ...hen compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check valve assembly clean or replace Do not disassemble check valve with air in tank bleed tank first Excessive moisture in discharge air 1 Excessive water in air receiver 1 Drain receiver 2 High humidity...

Page 8: ...ssure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified from factory settings 2 Lubricated Compressors a Pump wear or valve damage caused by using oil not specified b Pump wear or valve damage caused by any oil contamination or by failure to follow prope...

Page 9: ...r n est pas équipé pour et ne devrait pas être utilisé comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est nécessaire d équiper le compresseur d air pompe avec de l équipement de sécurité en canalisation et d alarme Cet équipement additionnel est nécessaire pour filtrer et purifier l air afin d atteindre les spécifications minimales pour la re...

Page 10: ... de faiblesse ou d usure et assurer que tous les raccordements sont sûrs ne pas utiliser si endommagé Contacter un centre de service autorisé pour l inspection ou la réparation Ne Pas faire fonctionner sans supervision Laisser le compresseur sur la position ON marche peut causer un démarrage accidentel Pour éviter un démarrage accidentel et de possibles dommages par surtension le mettre sur OFF ar...

Page 11: ... produits inflammables 3 Utiliser un respirateur pendant la pulvérisation 4 Ne pas diriger la peinture ou autre matériel pulvérisé vers le compresseur Situer le compresseur aussi loin que possible de l endroit de pulvérisation pour réduire l accumulation de surpulvérisation sur le compresseur 5 Suivre les instructions du fabriquant pendant la pulvérisation ou le nettoyage avec des solvants ou prod...

Page 12: ...le réservoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de manière appropriée Ce manomètre indique la pression maximum du compresseur quand il s éteigne automatiquement à la pression limite Robinet de Purge Ce robinet se trouve sous le réservoir Utiliser cette soupape pour purger l humidité du réservoir quotidiennement afin de r...

Page 13: ...isolant vert à l extérieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise à la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune à une borne électrisé Consulter un électricien ou réparateur qualifié si vous ne comprenez pas toutes les instructions ou si vous n êtes pas certain que le produit est bien mis à la terre Ne pas modifier la fiche...

Page 14: ...e pression de sortie dépassant la pression maximale indiquée de l accessoire Cycle marche arrêt du compresseur En position ON marche le compresseur pompe de l air dans le réservoir Lorsqu il atteint une pression d arrêt une coupure pré établie le compresseur s arrête automatiquement Si le compresseur reste en position ON marche et si l air sort complètement du réservoir en utilisant un mandrin de ...

Page 15: ...ur du réservoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut vérifier et nettoyer périodiquement le filtre à air dans le boîtier du filtre du côté de la tête et plus souvent s il est utilisé sous des conditions très poussièreuses ou lorsqu il y a beaucoup de brouillard créé par la pulvérisation et circulant près de l unité Important Le modèle doit être si...

Page 16: ...bre dans la section de Installation 3 Clapet ou déchargeur défectueux 3 Remplacer ou réparer Le protecteur de surcharge thermique se déclenche souvant 1 Tension basse 1 Vérifier avec un voltmètre 2 Filtre d air obstrué 2 Nettoyer le filtre voir la section d Entretien 3 Ventilation insuffisante température de l endroit trop haute 3 Déménager le compresseur à un endroit bien ventilé 4 Calibre de fil...

Page 17: ...17 Fr Série HG3000 Série HJ3001 Série HJ3002 Notes ...

Page 18: ...n de fils incorrecte g Autres articles pas indiqués mais considérés pièces à fatigue générales h Manostats régulateurs d air et soupapes de sûreté qui ont étés modifiés d après les réglages de l usine 2 Compresseurs Graissés a Usure de la pompe ou dommage aux soupapes causé par l utilisation d huile non spécifiée b Usure de la pompe ou dommage aux soupapes causé par toute contamination d huile ou ...

Page 19: ... compra con fecha para fines de la garantía Adjúntela a este manual o archívela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Portátiles ASME de 13 79 bar Por favor lea y guarde estas instrucciones Léalas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aquí descrito Protéjase usted mismo y a los demás observando tod...

Page 20: ...er si están deterioradas o hay fugas Antes de usarlo cerciórese de que las conecciones estén bien apretadas y no lo use si encuentra irregularidades Notifíquele a un centro de servicio autorizado para que lo chequeen o reparen No lo haga funcionar sin supervisión El dejar el compresor en la posición ON encindido puede causar que se encienda inadvertidamente Para prevenir que eso ocurra y posibles ...

Reviews: