installation 

(continued)

wirinG

 1.  Local electrical wiring codes differ 

from area to area. Source wiring, 
plug and protector must be rated for 
at least the amperage and voltage 
indicated on motor nameplate, and 
meet all electrical codes for this 
minimum.

 2.  Use a slow blow fuse type T or a 

circuit breaker.

 

Overheating, short  

  circuiting and fire 

damage will result from inadequate 
wiring, etc.
 

All wiring and  

  electrical 

connections should be performed by a 
qualified electrician. Installation must 
be in accordance with local codes and 
national electrical codes.

note: 

120 volt, compressor can be 

operated on a 120 volt, 15 amp circuit 
under the following conditions:

a. No other electrical appliances or 

lights are connected to the same 
branch circuit.

b. Voltage supply is normal.
c. Extension cords are of the 

minimum gauge specified in this 
instruction manual.

d. Circuit is equipped with a 15 amp 

circuit breaker or a 15 amp slow 
blow fuse type T.

 3.  If above conditions cannot be met 

or if nuisance tripping of current 
protection device occurs, it may be 
necessary to operate compressor 
from a 120 volt, 20 amp circuit.

GroUnDinG inStrUctionS

This product must be grounded.  In 
the event of an electrical short circuit, 
grounding reduces the risk of electric 
shock by providing an escape wire 
for the electric current.  This product 
is equipped with a cord having a 
grounding wire with an appropriate 
grounding plug.  The plug must be 
plugged into an outlet that is properly 
installed and grounded in accordance 
with all local codes and ordinances.

 

Improper installation  

  of the grounding 

plug is able to result in a risk of electric 
shock. When repair or replacement of the 
cord or plug is required, do not connect 
the grounding wire to either flat blade 
terminal.  The wire with insulation having 
an outer surface that is green with or 
without yellow stripes is the grounding 
wire.
 

Do not use a  

  grounding adapter 

with this product!

 

Never connect green  

  (or green and yellow) 

wire to a live terminal.

Check with a qualified electrician 
or serviceman when the grounding 
instructions are not completely 
understood, or when in doubt as 
to whether the product is properly 
grounded.  Do not modify the plug 
provided; if it does not fit the outlet, 
have the proper outlet installed by a 
qualified technician. 
This product is for use on a nominal 
120V circuit and has a grounding plug 
similar to the plug illustrated in  
Figure 4. Only connect the product to 
an outlet having the same configuration 
as the plug.  Do not use an adapter with 
this product.

extenSion corDS

 

To avoid loss  

  of power and 

overheating, it is better to use 
additional air hose instead of extension 
cords to reach work area. 

Use only a 3-wire extension cord that 
has a 3-blade grounding plug, and 
a 3-slot receptacle that accepts the 
plug on the product.  Make sure your 
extension cord is not damaged.  When 
using an extension cord, be sure to use 
one heavy enough to carry the current 
your product draws. An undersized 
cord results in a drop in line voltage 
and loss of power and overheating. 
[The table on page 5 shows the correct 
size to use depending on cord length 
and nameplate ampere rating. When in 
doubt, use the next heavier gauge. The 
smaller the gauge number, the heavier 
the cord.]

MoiStUre in coMpreSSeD air

Moisture in compressed air will form 
into droplets as it comes from an air 
compressor pump. When humidity 
is high or when a compressor is in 
continuous use for an extended period 
of time, this moisture will collect in 
the tank. When using a paint spray 
or sandblast gun, this water will be 
carried from the tank through the 
hose, and out of the gun as droplets 
mixed with the spray material.

iMportant: 

This condensation 

will cause water spots in a paint job, 
especially when spraying other than 
water based paints. If sandblasting, it 
will cause the sand to cake and clog 
the gun, rendering it ineffective. A 
filter in the air line, located as near to 
the gun as possible, will help eliminate 
this moisture.

TEST

RESET

Figure 4 - Grounding Method

Grounding 

Pin

Grounded 

Outlet

✽ 

wire and terminal Guide

wire

color

terminal

hot

Power cord

White

Line

No

Motor cord

White

Load

No

Power cord

Black

Line

Yes

Motor cord

Black

Load

Yes

(

When the unit is not in operation

Minimum Gauge of extension cords for 120v Unit

Motor amp 
rating range

length of cord 

25 feet

50 feet

100 feet

10-12 amp

16 

14

10

12-14 amp

16

12

10

14-16 amp

16

12

10

5

hG3000 Series, hJ3001 Series, hJ3002 Series

www.chpower.com

Summary of Contents for HG3000 Series

Page 1: ...is compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suitable in line safety and alarm equipment This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Ga...

Page 2: ...may allow it to turn on inadvertently To prevent this and possible damage from power surge turn to OFF position after each use 8 Release all pressures within system slowly dust and debris may be harmful Keep fingers away from a running compressor fast moving and hot parts will cause injury and or burns Disconnect power and depressurize system before servicing air compressor 9 Follow all local elec...

Page 3: ... the spraying area as possible to minimize overspray accumulation on the compressor 5 When spraying or cleaning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer 6 Do not smoke when spraying paint insecticides or other flammable substances 7 Use a face mask respirator when spraying and spray in a well ventilated area to prevent health and fire hazards 8...

Page 4: ...ressor is running indicating compressor is building pressure properly This gauge will show maximum pressure of compressor when it shuts off automatically at the pressure switch Drain Valve This valve is located underneath the tank Use this valve to drain moisture from the tank daily to reduce the risk of corrosion Drain liquid from tank daily Reduce tank pressure below 10 psi then drain moisture f...

Page 5: ...whether the product is properly grounded Do not modify the plug provided if it does not fit the outlet have the proper outlet installed by a qualified technician This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in Figure 4 Only connect the product to an outlet having the same configuration as the plug Do not use an adapter with this product...

Page 6: ...Valve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached see Operating Procedure 2 Wearing safety glasses pull the ring on the safety valve see Figure 5 to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your f...

Page 7: ...hen compressor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution and tighten 2 Loose drain lock 2 Tighten 3 Check valve leaking 3 Disassemble check valve assembly clean or replace Do not disassemble check valve with air in tank bleed tank first Excessive moisture in discharge air 1 Excessive water in air receiver 1 Drain receiver 2 High humidity...

Page 8: ...ssure switches e Drain cocks f Damage due to incorrect voltage or improper wiring g Other items not listed but considered general wear parts h Pressure switches air governors and safety valves modified from factory settings 2 Lubricated Compressors a Pump wear or valve damage caused by using oil not specified b Pump wear or valve damage caused by any oil contamination or by failure to follow prope...

Page 9: ...r n est pas équipé pour et ne devrait pas être utilisé comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est nécessaire d équiper le compresseur d air pompe avec de l équipement de sécurité en canalisation et d alarme Cet équipement additionnel est nécessaire pour filtrer et purifier l air afin d atteindre les spécifications minimales pour la re...

Page 10: ... de faiblesse ou d usure et assurer que tous les raccordements sont sûrs ne pas utiliser si endommagé Contacter un centre de service autorisé pour l inspection ou la réparation Ne Pas faire fonctionner sans supervision Laisser le compresseur sur la position ON marche peut causer un démarrage accidentel Pour éviter un démarrage accidentel et de possibles dommages par surtension le mettre sur OFF ar...

Page 11: ... produits inflammables 3 Utiliser un respirateur pendant la pulvérisation 4 Ne pas diriger la peinture ou autre matériel pulvérisé vers le compresseur Situer le compresseur aussi loin que possible de l endroit de pulvérisation pour réduire l accumulation de surpulvérisation sur le compresseur 5 Suivre les instructions du fabriquant pendant la pulvérisation ou le nettoyage avec des solvants ou prod...

Page 12: ...le réservoir pendant le fonctionnement du compresseur ce qui confirme que le compresseur est en train d augmenter la pression de manière appropriée Ce manomètre indique la pression maximum du compresseur quand il s éteigne automatiquement à la pression limite Robinet de Purge Ce robinet se trouve sous le réservoir Utiliser cette soupape pour purger l humidité du réservoir quotidiennement afin de r...

Page 13: ...isolant vert à l extérieur avec ou sans rayures jaunes est le fil de terre Ne pas utiliser d adaptateur de mise à la terre avec ce produit Ne jamais connecter le fil vert ou vert et jaune à une borne électrisé Consulter un électricien ou réparateur qualifié si vous ne comprenez pas toutes les instructions ou si vous n êtes pas certain que le produit est bien mis à la terre Ne pas modifier la fiche...

Page 14: ...e pression de sortie dépassant la pression maximale indiquée de l accessoire Cycle marche arrêt du compresseur En position ON marche le compresseur pompe de l air dans le réservoir Lorsqu il atteint une pression d arrêt une coupure pré établie le compresseur s arrête automatiquement Si le compresseur reste en position ON marche et si l air sort complètement du réservoir en utilisant un mandrin de ...

Page 15: ...ur du réservoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut vérifier et nettoyer périodiquement le filtre à air dans le boîtier du filtre du côté de la tête et plus souvent s il est utilisé sous des conditions très poussièreuses ou lorsqu il y a beaucoup de brouillard créé par la pulvérisation et circulant près de l unité Important Le modèle doit être si...

Page 16: ...bre dans la section de Installation 3 Clapet ou déchargeur défectueux 3 Remplacer ou réparer Le protecteur de surcharge thermique se déclenche souvant 1 Tension basse 1 Vérifier avec un voltmètre 2 Filtre d air obstrué 2 Nettoyer le filtre voir la section d Entretien 3 Ventilation insuffisante température de l endroit trop haute 3 Déménager le compresseur à un endroit bien ventilé 4 Calibre de fil...

Page 17: ...17 Fr Série HG3000 Série HJ3001 Série HJ3002 Notes ...

Page 18: ...n de fils incorrecte g Autres articles pas indiqués mais considérés pièces à fatigue générales h Manostats régulateurs d air et soupapes de sûreté qui ont étés modifiés d après les réglages de l usine 2 Compresseurs Graissés a Usure de la pompe ou dommage aux soupapes causé par l utilisation d huile non spécifiée b Usure de la pompe ou dommage aux soupapes causé par toute contamination d huile ou ...

Page 19: ... compra con fecha para fines de la garantía Adjúntela a este manual o archívela en lugar seguro IN634100AV 7 10 2010 Campbell Hausfeld Scott Fetzer Compresores de Aire Portátiles ASME de 13 79 bar Por favor lea y guarde estas instrucciones Léalas cuidadosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aquí descrito Protéjase usted mismo y a los demás observando tod...

Page 20: ...er si están deterioradas o hay fugas Antes de usarlo cerciórese de que las conecciones estén bien apretadas y no lo use si encuentra irregularidades Notifíquele a un centro de servicio autorizado para que lo chequeen o reparen No lo haga funcionar sin supervisión El dejar el compresor en la posición ON encindido puede causar que se encienda inadvertidamente Para prevenir que eso ocurra y posibles ...

Reviews: