Operation

Definition of Terms

ON / OFF Switch ( I / O )

- Push switch

to the ON ( 

I

) position to turn

compressor on. Push switch to the OFF (

O

) position to turn compressor off. This

switch should be in the OFF (

O

)

position when connecting /
disconnecting power cord from
electrical outlet or when changing tools.

Pressure Switch (located internally)

-

When the compressor is turned ON,
this switch will shut compressor off
automatically when tank pressure
reaches maximum shut-off / cut-out
pressure. If compressor remains on and
air is depleted from tank, this switch
will allow compressor to automatically
restart at the restart / cut-in pressure.

Regulator

- The regulator controls the

amount of air pressure released at the
hose outlet. Turning the regulator knob
clockwise (to the right) will increase air
pressure at the outlet. Turning the knob
counter-clockwise (to the left) will lower
air pressure to the outlet. Turning knob
fully counter-clockwise will shut off flow
of air completely.

Pressure Gauges

- There are two

gauges located next to the regulator.
These gauges read air pressure in
pounds per square inch (psi) The larger
gauge shows pressure at the outlet.
Make sure this gauge reads ZERO (by
adjusting the regulator) BEFORE
changing air tools or disconnecting hose
from outlet. The small gauge shows
pressure in the tank indicating
compressor is building pressure properly. 

ASME Safety Valve

- This valve

automatically releases air if the tank
pressure exceeds the preset maximum.

Handle 

- Designed to move the

compressor.

Drain Valve

- This valve is located on

the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.

Motor Reset - 

(not shown, located

inside motor). Designed to keep the
motor from overheating. The motor
has an auto reset protector. To reset
once the motor has cooled, turn the
switch to the OFF position, then to the
ON position.

This compressor is
equipped with an

overload protector which will shut off
motor if it becomes overloaded.

If the overload
protector is

actuated, the motor must be allowed to
cool down for approximately 30 minutes
before it will reset.

LUBRICATION

This is an oilless product and 

D

DO

OE

ES

S

N

NO

OT

T

require lubrication to operate.

BEFORE FIRST STARTUP
BREAK-IN PROCEDURE

(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise

(to the right) to open air flow.

2. Do not attach a hose or any other

fitting to the compressor.

3. Turn on/off switch to OFF position.

4. Plug in power cord.

5. Turn on/off switch to ON position.

Allow compressor to run for 5 min.

6. Turn on/off switch to OFF position.

7. Unplug power cord.

BEFORE EACH STARTUP
OPERATING PROCEDURE

1. Turn switch to OFF ( 

O

) position and

plug in power cord.

2. Turn regulator knob

counterclockwise to close air flow.

3. Turn switch to ON ( 

I

) position.

4. Compressor will build to maximum

pressure and shut off.

5. With hose attached to outlet of

compressor, attach tire chuck or
other tool to open end of hose. 

6. Adjust regulator to proper pressure

for tool or tire. Operate tool per
instructions. 

As air is depleted from the tank by use
of a tire chuck, tool, etc., the
compressor will restart automatically at
its preset “cut-in” pressure. When a
tool is being used continuously, the
compressor will cycle on and off
automatically. 

7. Turn switch to OFF ( 

O

) position,

unplug power cord and drain tank of
air when finished using compressor.

Figure 4

ON/OFF Switch

Drain Valve

Safety Valve

Pressure Gauge

Handle

Figure 2 - Unit Identification

Drain Valve

Regulator Knob

Air outlet

OFF Position

Figure 3

ON Position

Summary of Contents for FP209699

Page 1: ...tentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate inju...

Page 2: ...o prevent health and fire hazards 18 Do not direct paint or other sprayed material at the compressor Locate compressor as far away from the spraying area as possible to minimize overspray accumulation...

Page 3: ...nside motor Designed to keep the motor from overheating The motor has an auto reset protector To reset once the motor has cooled turn the switch to the OFF position then to the ON position This compre...

Page 4: ...ad protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor OFF frequently look for the following causes 1 Low voltage 2 Lack of proper ventilation If the...

Page 5: ...5 Notes FP209501 FP209598 FP209599 FP209601 FP209699...

Page 6: ...where temperature will not exceed 100 F 5 Check all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated...

Page 7: ...ic base 1 25 Pressure switch tube kit FP209535AV 1 26 Cap see part 10 1 27 Spring see part 10 1 28 Tank 1 29 Screw 2 30 Washer 2 31 Screw 4 32 Nut 4 33 Screw 4 34 Wire Clip FP202823AV 1 35 Screw 1 36...

Page 8: ...E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or a...

Page 9: ...rrer tout raccord boulon etc avant de mettre ce produit en service En cas de dommage ou de parties manquantes S V P composer le 1 800 543 6400 pour demander conseil Pri re d avoir le num ro de s rie n...

Page 10: ...vante peut agiter la poussi re et le d bris qui peut tre dangereux L cher l air lentement en purgeant l humidit ou pendant la d pressurisation du syst me du compresseur 14 Utilisation d int rieur seul...

Page 11: ...r gulateur sert r gler la pression d air la sortie du tuyau Le bouton du r gulateur se tourne dans le sens horaire droite pour augmenter la pression d air la sortie Le bouton du r gulateur se tourne d...

Page 12: ...doit tre r alis seulement par un repr sentant de service autoris Inspecter le compresseur souvant et suivre les proc d s d entretien suivants pendant chaque utilisation du compresseur SOUPAPE DE S RE...

Page 13: ...OFF ARR T 2 D brancher le cordon d alimentation de la prise et l enrouler autour du manche pour viter de l endommager pendant l entreposage 3 En portant des lunettes de s curit vidanger l air du r ser...

Page 14: ...pas 38 C 100 F 5 V rifier toutes les connexions lectriques 6 Remplacer l interrupteur ON OFF 7 Remplacer le pressostat 8 Remplacer le montage de pompe moteur 1 D placer le compresseur dans un endroit...

Page 15: ...usse de pressostat FP209538AV 1 10 Soupape de retenue Inclut 26 et 27 FP209532AV 1 11 Vis M4x0 7x6 1 12 Vis M6x1 0x10 4 13 Robinet de purge D 1403 1 14 Pieds en caoutchouc R servoir FP209522AV 4 15 Fi...

Page 16: ...ints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un m...

Page 17: ...ltos antes de poner la unidad en servicio En el caso de que haya da o o partes que faltan haga el favor de llamar al 1 800 543 8622 para obtener ayuda Tenga a mano el n mero de serie el n mero del mod...

Page 18: ...e inspeccionar peri dicamente para detectar condiciones de peligro como la formaci n de xido y corrosi n 13 La circulaci n r pida de aire podr a levantar polvo y desperdicios da inos Siempre libere el...

Page 19: ...expulsada por la manguera Al girar la perilla del regulador en sentido horario hacia la derecha la presi n de aire a la salida aumenta Al girar la perilla en sentido antihorario hacia la izquierda la...

Page 20: ...or un representante de servicio autorizado Este compresor se debe chequear con frecuencia para ver si tiene alg n tipo de problemas y le debe dar el siguiente mantenimiento antes de cada uso VALVULA D...

Page 21: ...enchufe el cord n del tomacorrientes de pared y envu lvalo alrededor del mango para prevenir da os cuando no se use 3 Con las gafas de seguridad puestas descargue el aire del tanque halando el anillo...

Page 22: ...tura no exceda los 100 F 5 Verifique todas las conexiones el ctricas 6 Reemplace el interruptor ON OFF 7 Cambie el interruptor de presi n 8 Reemplace el ensamble de la bomba motor 1 Mueva el compresor...

Page 23: ...de interruptor de presi n FP209538AV 1 10 Valvula de chequeo incluye 26 y 27 FP209532AV 1 11 Tornillo M4x0 7x6 1 12 Tornillo M6x1 0x10 4 13 V lvula de drenaje D 1403 1 14 Patas de caucho Tanque FP2095...

Page 24: ...o cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instr...