Never

connect

green (or green and yellow) wire to a
live terminal.

3. Check with a qualified electrician or

serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.

Overheating, short circuiting and fire
damage will result from inadequate
wiring, etc.

Operation

DEFINITION OF TERMS

ON / OFF Switch ( I / O )

- Push switch

to the ON ( 

I

) position to turn

compressor on. Push switch to the OFF

O

) position to turn compressor off.

This switch should be in the OFF (

O

)

position when connecting /
disconnecting power cord from
electrical outlet or when changing
tools.

Pressure Switch (located internally)

-

When the compressor is turned ON,
this switch will shut compressor off
automatically when tank pressure
reaches maximum shut-off / cut-out
pressure. If compressor remains on and
air is depleted from tank, this switch
will allow compressor to automatically
restart at the restart / cut-in pressure.

Pressure Gauge

- This gauge reads air

pressure in pounds per square inch
(psi) in the compressor tank. Make sure
this gauge reads ZERO BEFORE
changing air tools or disconnecting
hose from outlet. 

ASME Safety Valve

- This valve

automatically releases air if the tank
pressure exceeds the preset maximum.

Handle 

- Designed to move the

compressor.

Drain Valve

- This valve is located on

the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.

LUBRICATION

This is an oilless product and 

DOES

NOT

require lubrication to operate.

BEFORE FIRST STARTUP
BREAK-IN PROCEDURE

(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to
repeat.)
1. Turn regulator knob fully clockwise

(to the right) to open air flow.

2. Do not attach a hose or any other

fitting to the compressor.

3. Turn on/off switch to OFF position.

4. Plug in power cord.

5. Turn on/off switch to ON position.

Allow compressor to run for 5
minutes.

6. Turn on/off switch to OFF position.

7. Unplug power cord.

BEFORE EACH STARTUP

OPERATING PROCEDURE

1. Connect air hose to open port

located below pressure gauge.

2. Attach the necessary fitting or tool

to open end of air hose.

3. Turn on/off switch to OFF ( 

O

)

position.

4. Plug in power cord.

5a.

If using inflation needles/nozzles:

Attach air hose with inflation
fitting to the object you are going
to inflate. While holding inflation
fitting firmly in place, turn on/off
switch to ON position. Allow
compressor to inflate the object.
Turn off compressor and remove
inflation fitting.

5b.

If using tire chuck or tool: 

Once

chuck or tool is attached to air
hose, turn on/off switch to ON
position and allow compressor to
run until it automatically shuts off.
When using tire chuck to inflate
tires, observe gauge reading on
compressor and periodically check
tire pressure with a separate tire
gauge to prevent overinflation.

6. Operate tool per instructions. 

As air is depleted from the tank by use
of a tire chuck, tool, etc., the
compressor will restart automatically at
its preset “cut-in” pressure. When a
tool is being used continuously, the
compressor will cycle on and off
automatically.

ON/OFF Switch

Drain Valve

Safety Valve

Pressure Gauge

Handle

Figure 2 - Unit Identification

FP202801, FP202901, FP202897, FP202999DB, FP202999DQ, and FP202899TT

Air Outlet

OFF Position

Figure 3

ON Position

Figure 4

Summary of Contents for FP2028999TT

Page 1: ...LD result in death or serious injury Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not...

Page 2: ...ancer and birth defects Wash hands after handling SPRAYING PRECAUTIONS Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit 16 Do not smoke...

Page 3: ...ubrication to operate BEFORE FIRST STARTUP BREAK IN PROCEDURE Complete this procedure before using compressor for the first time Once completed it is not necessary to repeat 1 Turn regulator knob full...

Page 4: ...load protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor OFF frequently look for the following causes 1 Low voltage 2 Lack of proper ventilation If t...

Page 5: ...eck all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated area where temperature will not exceed 100 F...

Page 6: ...Oilless Compressors 6 16 22 19 14 13 2 8 9 10 12 7 6 5 3 17 15 11 26 24 21 18 1 4 27 28 25 29 30 20 31 Figure 7 23 32...

Page 7: ...11 M4 x 0 7 x 6 screw 1 12 M6 x 1 0 x 10 screw 4 13 Drain valve D 1403 1 14 Rubber feet tank FP202828AV 3 15 Wire pressure switch to power switch FP209523AV 1 16 Power cord Strain relief FP209534AV 1...

Page 8: ...ents are expressly excluded from coverage under this limited warranty The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product G Additional items...

Page 9: ...P composer le 1 800 543 6400 pour demander conseil Une liste de centres de services est ciinclus Pri re d avoir le num ro de s rie S il vous pla t lire et conserver ces instructions Lire attentivement...

Page 10: ...ou pendant la d pressurisation du syst me du compresseur 15 Utilisation d int rieur seulement 16 Pour r duire le risque de choc lectrique ne pas exposer la pluie Ranger l int rieur PR CAUTIONS DE PULV...

Page 11: ...servoir du compresseur S assurer que le manom tre est ZERO AVANT de changer les outils pneumatiques ou avant de d brancher le tuyau de la sortie Soupape de S ret ASME Cette soupape laisse chapper l ai...

Page 12: ...ape de s ret pour d gager la pression du r servoir du compresseur Utiliser l autre main pour loigner l air se d pla ant rapidement du visage 3 La soupape de s ret se fermera automatiquement environ 27...

Page 13: ...y a une fuite resserrer Ou retirer le raccord et appliquer un ruban tuyau sur les filets puis remonter Ne pas d monter le clapet Avec de l air dans le r servoir purger le r servoir d abord 3 V rifier...

Page 14: ...Compresseur Sans Huile 14 Fr 16 22 19 14 13 2 8 9 10 12 7 6 5 3 17 15 11 26 24 21 18 1 4 27 28 25 29 30 20 31 Figure 7 23 32...

Page 15: ...39AV 1 19 Couvercle de moteur 1 20 Attache de fils FP202823AV 1 21 Kit de tuyau de ventilation FP202839AV 1 22 Trousse de douille de l isolateur du moteur FP209037AV 1 23 Accessoires FP204008AV 1 24 c...

Page 16: ...arantie limit e L acheteur doit observer la garantie du fabricant de moteur qui est fournie avec le produit G Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Tous les Compresse...

Page 17: ...los accesorios pernos etc que est n sueltos antes de poner la unidad en servicio En el caso de que haya da o o partes que faltan haga el favor de llamar al 1 800 543 6400 para obtener ayuda S rvase le...

Page 18: ...e xido y corrosi n 14 La circulaci n r pida de aire podr a levantar polvo y desperdicios da inos Siempre libere el aire lentamente para drenar el tanque o liberar la presi n del sistema 15 Uso de inte...

Page 19: ...guera V lvula de seguridad ASME Esta v lvula autom ticamente libera el aire si la presi n del tanque excede el valor m ximo fijado de f brica Mango Dise ado para mover el compresor Llave de drenaje Es...

Page 20: ...de cada uso VALVULA DE SEGURIDAD ASME Nunca desconecte o trate de ajustar la v lvula de seguridad ASME Revise la v lvula de seguridad siguiendo los siguientes pasos 1 Enchufe el compresor y h galo fun...

Page 21: ...una soluci n de agua y jab n Si se detecta una fuga apriete O quite la conexi n y aplique cinta para tuber as a las rocas y vuelva a armar No desarme la v lvula de retenci n Si hay aire en el tanque...

Page 22: ...Compresores Sin Aceite 22 Sp 16 22 19 14 13 2 8 9 10 12 7 6 5 3 17 15 11 26 24 21 18 1 4 27 28 25 29 30 20 31 Figura 7 23 32...

Page 23: ...V 1 19 Cubierta del motor 1 20 Sujetador del cable FP202823AV 1 21 Kit de tubo de escape FP202839AV 1 22 Juego de buje del aislador del motor FP209037AV 1 23 Accesorios FP204008AV 1 24 Tuerca 4 25 Tor...

Page 24: ...mprador debe seguir las clausulas de la garant a otorgada por el fabricante del motor de gasolina que se suministra con el producto G Art culos adicionales no cubiertos bajo esta garant a 1 Todos los...

Reviews: