7
LP tank must be arranged for vapour
withdrawal.
LP (Liquefied Petroleum Gas)
• LP gas is non-toxic, odourless and
colourless when produced. For Your Safety,
LP gas has been given an odour (similar to
rotten cabbage) so that it can be smelled.
• LP gas is highly flammable and may ignite
unexpectedly when mixed with air.
LP Tank Filling
• Use only licensed and experienced dealers.
• LP dealer must purge tanks before filling.
• Dealer should NEVER fill LP tank more than
80% of LP tank volume. Volume of propane
in tanks will vary by temperature.
• A frosty regulator indicates gas overfill.
Immediately close LP tank valve and call
local LP gas dealer for assistance.
• Do not release liquid propane (LP) gas
into the atmosphere. This is a hazardous
practice.
• To remove gas from LP tank, contact an
LP dealer or call a local fire department for
assistance. Check the telephone directory
under “Gas companies” for nearest certified
LP dealers.
LP Tank Exchange
• Many retailers that sell appliances offer you
the option of replacing your empty LP tanks
through an exchange service. Use only those
reputable exchange companies that inspect,
precision fill, test and certify their cylinders.
Exchange your tank only for an OPD safety
feature-equipped tank as described in the
“LP Tank” section of this manual.
• Always keep new and exchanged LP tanks
in upright position during use, transit or
storage.
• Leak test new and exchanged LP tanks
BEFORE connecting to appliance.
LP Tank Leak Test
WARNING
Appliance must be leak checked outdoors
in well-ventilated area, away from ignition
sources such as gas fired or electrical
appliances. During leak test, keep appliance
away from open flames or sparks.
For your Safety
• Leak test must be repeated each time LP
tank is exchanged or refilled.
• Do not smoke during leak test.
• Do not use an open flame to check for gas
leaks.
Use a clean paintbrush and 50/50 soap and
water solution. Use mild soap and water. Do
not use household cleaning agents. Damage
to gas train components can result. Brush
soapy solution onto all weld seams and entire
valve area.
WARNING
If “growing” bubbles appear, do not use
or move the LP tank. Contact an LP gas
supplier or your fire department.
Connecting Regulator to Appliance
Use an adjustable or 19 mm / 3/4 in wrench
to connect the regulator hose to the cooking
system. Tighten securely with wrench. Do not
use appliance before checking for leaks. See
section Leak Testing.
Connecting Regulator to the LP Tank
Only use the pressure
regulator and hose supplied
with this appliance. Regulator
Model RJ-C, RA329, JY95A7A
(JY95-007)
1. Place LP tank on a secure,
level, and stable surface.
2. Turn control knob to the
OFF position.
3. Turn LP tank OFF by turning hand wheel
clockwise to a full stop.
4. Remove the protective cap from LP tank
valve.