Continuation Table 10: 3X and 4X register addresses for measured parameters
Address
(3X Register)
Address
(4X Register)
Parameter
Parameter
No.
Start address Hex 3X Start address Hex 4X
High Byte Low Byte High Byte Low Byte
30243
44339
Energy export old channel 3 OFF
121
00
F2
10
F2
30245
44341
Energy export old channel 4 OFF
122
00
F4
10
F4
30247
44343
Ampere hour import old channel 1
123
00
F6
10
F6
30249
44345
Ampere hour import old channel 2
124
00
F8
10
F8
30251
44347
Ampere hour import old channel 3
125
00
FA
10
FA
30253
44349
Ampere hour import old channel 4
126
00
FC
10
FC
30255
44351
Ampere hour export old channel 1
127
00
FE
10
FE
30257
44353
Ampere hour export old channel 2
128
01
00
11
00
30259
44355
Ampere hour export old channel 3
129
01
02
11
02
30261
44357
Ampere hour export old channel 4
130
01
04
11
04
30263
44359
Max power demand import old channel 1
131
01
06
11
06
30265
44361
Max power demand import old channel 2
132
01
08
11
08
30267
44363
Max power demand import old channel 3
133
01
0A
11
0A
30269
44365
Max power demand import old channel 4
134
01
0C
11
0C
30271
44367
Max power demand export old channel 1
135
01
0E
11
0E
30273
44369
Max power demand export old channel 2
136
01
10
11
10
30275
44371
Max power demand export old channel 3
137
01
12
11
12
30277
44373
Max power demand export old channel 4
138
01
14
11
14
30279
44375
Max current demand import old channel 1
139
01
16
11
16
30281
44377
Max current demand import old channel 2
140
01
18
11
18
30283
44379
Max current demand import old channel 3
141
01
1A
11
1A
30285
44381
Max current demand import old channel 4
142
01
1C
11
1C
30287
44383
Max current demand export old channel 1
143
01
1E
11
1E
30289
44385
Max current demand export old channel 2
144
01
20
11
20
30291
44387
Max current demand export old channel 3
145
01
22
11
22
30293
44389
Max current demand export old channel 4
146
01
24
11
24
30295
44391
On hour old
147
01
26
11
26
30297
44393
Run hour old channel 1
148
01
28
11
28
30299
44395
Run hour old channel 2
149
01
2A
11
2A
30301
44397
Run hour old channel 3
150
01
2C
11
2C
30303
44399
Run hour old channel 4
151
01
2E
11
2E
30305
44401
No. of interruptions old
152
01
30
11
30
30307
44403
Energy import channel 1 OFF
153
01
32
11
32
30309
44405
Energy import channel 2 OFF
154
01
34
11
34
30311
44407
Energy import channel 3 OFF
155
01
36
11
36
30313
44409
Energy import channel 4 OFF
156
01
38
11
38
30315
44411
Energy export channel 1 OFF
157
01
3A
11
3A
30317
44413
Energy export channel 2 OFF
158
01
3C
11
3C
30319
44415
Energy export channel 3 OFF
159
01
3E
11
3E
30321
44417
Energy export channel 4 OFF
160
01
40
11
40
30323
44419
Total energy import OFF
161
01
42
11
42
30325
44421
Total energy export OFF
162
01
44
11
44
30327
44423
Ampere hour import channel 1 OFF
163
01
46
11
46
30329
44425
Ampere hour import channel 2 OFF
164
01
48
11
48
30331
44427
Ampere hour import channel 3 OFF
165
01
4A
11
4A
30333
44429
Ampere hour import channel 4 OFF
166
01
4C
11
4C