12
ON
SINEAX
TV 808
(10)
(11)
(12) (5)
ON
(8)
(9)
(7)
(6)
(2)
without
function
Camille Bauer AG
CH-5610 Wohlen
Switzerland
Fig. 2
(2)
Front plate
(5)
Type label
(6)
Transparent cover
(7)
Fixing bracket
(8)
Opening for withdrawing clip (for opening the housing)
(9)
Top-hat rail 35
×
15 mm or 35
×
7.5 mm (EN 50 022)
(10) Terminals
(11) Terminals
(12) Space for notes
ON
Green LED for indicating device standing by
6. Technical data
Measuring input
DC current:
Standard ranges 4…20 mA
Limit values
0…0.1 to 0…40 mA
also live-zero,
start value > 0 to
≤
50% final va-
lue
– 0.1…0…+ 0.1 to
–20…0…+ 20 mA
max. span:
≤
40 mA
also bipolar asymmetrical
R
i
= 15
Ω
DC voltage:
Limit values
0…0.06 to 0…40,
also live-zero,
start value > 0 to
≤
50% final va-
lue
– 0.06…0…+ 0.06 to
–20…0…+ 20 V,
max. span:
≤
40 V
R
i
= 100 k
Ω
Overload:
DC current
continuously 2-fold
DC voltage
continuously 2-fold
Measuring output
DC current:
Standard ranges
4…20 mA, 0 … 20 mA
invert
20 … 4 mA, 20 … 0 mA
Burden voltage/
external resistance:
Standard version,
20 V / R
ext
max. 1000
Ω
Ex version,
15 V / R
ext
max. 750
Ω
Current limiter at
R
ext
max.:
Approx. 1.1
×
I
AN
Voltage limiter
at R
ext
=
∞
:
Approx. 26 V
Residual ripple in
output current:
< 0.5% p.p.
Response time:
< 50 ms
Power supply H
AC/DC power pack (DC and 45...400 Hz)
Table 1: Nominal voltages and tolerances
Nominal voltage U
N
Tolerance
Instruments
version
24... 60 V DC/AC
DC – 15…+ 33%
AC ± 15 %
Standard
(Non-Ex)
85…230 V
1
DC/AC
24… 60 V DC/AC
In
type of
protection
intrinsically safe
[EEx ia] IIC
85…230 V AC
± 10%
85…110 V DC
– 15 … + 10%
1
For power supply > 125 V, the auxiliary circuit should include an
external fuse with a rating
≤
20 A DC.
Power input:
≤
1.2 W resp.
≤
3 VA
Accuracy data
(acc. to DIN/IEC 770)
Basic accuracy:
Limit error
≤
± 0.2%
Including linearity and reproduci-
bility errors
Installation data
Terminals:
DIN/VDE 0609
Screw terminals with wire guards,
for light PVC wiring and
max. 2
×
0.75 mm
2
or 1
×
2,5 mm
2
Permissible vibrations: 2 g acc. to EN 60 068-2-6
Shock:
3
×
50 g
2 shocks each in 6 directions acc.
to EN 60 068-2-27
Electrical insulation:
All circuits (measuring input/measu-
ring output/power supply) are elec-
trically insulated