MC-II Flow Analyzer
14
Enter the Calibration
factor from your turbine
flowmeter.
(Applicable only when
preprogrammed unit is
selected for volume.)
Set unit of measure for
RATE.
Factory default setting is bpd.
3.
Locate the calibration factor (pulses per gallon) of the turbine flow-
meter. This factor is typically recorded on a plastic tag attached to the
meter. Enter the number into the MC-II as follows:
a.
Press
DEC. POINT
repeatedly to position your decimal point in
the proper position for your calibration factor.
b.
Enter digits from right to left. The right-most digit will flash,
indicating the digit being changed.
c.
Press
INCREMENT
repeatedly to advance the digits from 0 to
9, or press and hold
INCREMENT
to scroll through the digits to
make the appropriate selection. Then, press
ENTER/STEP
to
save it and advance to the next digit. Repeat this step to enter all
six digits.
d.
If your calibration factor is less than six digits in length, enter 0
for each of the unused digits at the left.
When you have entered the last of the six digits and pressed
ENTER/
STEP
, the calibration factor will be saved in the MC-II’s memory
and the
rAt.Eng
menu will appear in the top display.
4.
At the
rAt.Eng
prompt, select a unit of measure for rate:
•
barrels per day (b.P.d)
•
gallons per minute (g.P.nn)
•
cubic meters per day (nn3.P.d)
•
liters per minute (Lit.P.nn)
•
<preselected volume unit> per day (PEr.dAY)
•
<preselected volume unit> per hour (PEr.Hr)
•
<preselected volume unit> per minute (Prnn in)
•
<preselected volume unit> per second (PEr.SEC)
To select a unit of measure, press
INCREMENT
repeatedly until
the appropriate unit of measure appears in the bottom display. Press
ENTER/STEP.
If you selected a user-defined unit of measure for volume in Step 2,
your rate unit options will be per day, per hour, per minute, or per
second.
The
PULSE
menu will appear in the top display.
Summary of Contents for NuFlo MC-II
Page 1: ...NUFLO MC II FlowAnalyzer User Manual Manual No 100079666 Rev OE ...
Page 6: ...MC II Flow Analyzer 2 Figure 1 Nomenclature exterior ...
Page 7: ...MC II Flow Analyzer 3 Figure 2 Nomenclature interior ...
Page 32: ...MC II Flow Analyzer 28 ...
Page 38: ...MC II Flow Analyzer 34 ...
Page 44: ...40 MC II Flow Analyzer ...
Page 45: ......
Page 46: ......