M08627;33/39
- 33 -
●
Vertical timing: Continuous shutter, No shutter/Normal scan/No fast dump
VD
9
(Vertica l synchro nous signa l)
1Vertica l
pe ri o d
(1 V) = 1 fra me t ime
2056
3
CCD output signal
Internal
signal
Effective imag e(1960 )
1
9
6
0
1
9
6
0
O B ( 2 )
End of exp osu re
( Sensor G ate)
3
O B ( 8 )
Blank
tr ans fe r
( 8 6 )
2
4
3
5
1
O B ( 2 )
3
1
9
6
0
1
9
6
0
O B ( 2 )
O B ( 8 )
2
4
3
5
1
O B ( 2 )
8
8
FDV
Image
o utp ut
Image signal
( Digital)
B la nk
trans fer
( 8 6 )
Effect ive image
d u ra t io n
(1960 )
Effect ive
imag e
du ra t io n
I ne
ffective
image duration (
9 6 )
* Unless otherwise specified, the time unit of the numbers in the vertical timing chart is H(= 3156 PCLK =1920 x 1/32.50MHz
= 97.11
µ
S).
●
Vertical timing: High speed/preset shutter/asynchronous shutter/normal scan/No fast dump
HD
Vinit
Exp osu re time (n H)
n
F D V
Hor izontal
synchro nous signa l
1
96
0
3
Int ernal
signal
(Internal
oper ation
)
End of ex pos ure(SG)
2
4
3
5
Image signal
Effective ima ge durat ion (1960)
20 5 4
1
n+ 2
STRB
8
( Dig ital)
Image
output
1
0. 1 3
0. 15
0.3
Per iod where it is reg arded inva lid to ne wly input trigger s ign al
* Unless otherwise specified, the time unit of the numbers in the vertical timing chart is H(= 3156 PCLK =1920 x 1/32.50MHz
= 97.11
µ
S).