M08627;12/39
- 12 -
(4-9) Operation confirmation buzzer
This equipment is designed to sound the confirmation buzzer of “pip” when a stroke is applied to the UP/DOWN switch on
the rear panel, or at the time of other manipulation including the start-up after power application.
The factory default setting is ON. This setting can be changed to cancel the buzzer.
[Procedure for switching buzzer between ON/OFF]
●
Start up in the Setting Group C. (Set the mode switch to the position “C” while the power is turned off. Then apply the
power while the UP/DOWN switch is positioned to either side.)
●
Change the mode switch to the position 2” after confirming that the orange LED is flashing.
●
When an upward stroke is applied to the UP/DOWN switch, the buzzer is set to be ON. When a downward stroke is
applied, it is set to be OFF.
●
Simply turn off the power after the setting is complete. (The setting is saved.)
(4-10) Camera ID saving function
The ID code and other information set by the user for each camera can be stored in the camera and read out wherever
necessary.
The saved identification data for each camera including installation location in the case of using more than one camera
(e.g., “CAMERA-RIGHT” and “CAMERA-LEFT”) allows the user to easily control and identify the camera (s).
The setting is executed through the serial communication. The settable maximum number of characters are 15, and
alphanumeric characters (both uppercase and lowercase characters) and some special symbols such as ”+” and “-”
excluding the control codes can be used.
(
→
Refer to the section of “Serial Communication Control” for the details.)