Types of cables and minimum thicknesses
N.B.: If the cables differ in length compared to what is shown in the table, the cable cross-section is determined according
to the actual current draw of the devices connected and according to the provisions of the IEC EN 60204-1 standard.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual
power draw and distances. When connecting products that are not specified in this manual, please refer to the documen-
tation provided with said products.
Connection
Type of
cable
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Control panel power supply 230V
FROR CEI
20-22
IEC EN
50267-2-1
3G x 1.5 mm²
3G x 2.5 mm²
3G x 4 mm²
Motor power supply 24 V DC
4G x 1,5 mm²
4G x 1.5 mm²
4G x 2.5 mm²
Flashing light
2 x 0.5 mm²
2 x 1 mm²
2 x 1.5 mm²
Photocell transmitters
2 x 0.5 mm²
2 x 0.5 mm²
2 x 0.5 mm²
Photocell receivers
4 x 0.5 mm²
4 x 0.5 mm²
4 x 0.5 mm²
Accessory power supply
2 x 0.5 mm²
2 x 0.5 mm²
2 x 1 mm²
Control and security devices
2 x 0.5 mm²
2 x 0.5 mm²
2 x 0.5 mm²
Antenna connection
RG58
max. 10 m