MALFUNCTIONS

POSSIBLE CAUSES

CHECKS AND REMEDIES

The gate does not open or close

•  No power supply
•  The transmitter battery is flat
•  The transmitter is broken
•  The stop button is stuck or broken
•  The opening/closing button or the key 

selector switch are stuck

• Check for power
• Replace the batteries
• Contact service
• Contact service
• Contact service

The gate opens but does not close

• The photocells are engaged

• Check that the photocells are 

clean and work correctly

• Contact service

The flashing light does not work

•  The bulb has blown

• Contact service

Troubleshooting

Maintenance

Periodic maintenance log to be completed by the user (every six months)

Date

Notes Signature

 

Before any maintenance, disconnect power to prevent any possible dangerous situations that can be caused by 

accidental movement of the device.

Summary of Contents for STYLO ME

Page 1: ...EXTERNAL OPERATOR FOR SWING GATES Installation manual STYLO STYLO ME STYLO RME English EN 119DV11EN ...

Page 2: ...d Check that any lawn watering devices will not wet the operator from the bottom up Installation Carefully section off the entire site to prevent unauthorised access especially by minors and children Be careful when handling ope rators that weigh more than 20 kg In such cases use proper weight handling safety equipment All opening commands e g buttons key selector switches magnetic detectors etc m...

Page 3: ...ny other chemicals as these could damage the devices If the system requires repairs or modifications release the operator and do not use it until safe ty conditions have been restored Cut off the power supply before releasing the operator for manual openings and before any other operation to prevent dangerous situations Read the instructions Users are STRICTLY FORBIDDEN from performing OPERATIONS N...

Page 4: ...tial and apartment block swing gates Any use other than that described above and installations that differ from what is set out in this technical manual are forbidden This product has been designed and built by CAME S p A in compliance with applicable safety standards The full range 001STYLO ME 24 V DC non reversible external gearmotor 001STYLO RME 24 V DC reversible external gearmotor Mandatory a...

Page 5: ...re subject to change at any time without prior notice EN Technical data Type STYLO ME STYLO RME Protection rating IP54 Power supply 230 V AC 50 60 Hz Motor power supply 24 DC 50 60 Hz Current draw max 5 A Power 48 W Maximum torque 100 Nm Opening time 90 adjustable Duty cycle intensive use Operating temperature C 20 55 Gear ratio 1 531 Weight kg 6 8 kg Dimensions mm ...

Page 6: ... time without prior notice Page 6 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN 1 Main body of the gearmotor 2 Upper cap 3 Lower cap 4 Hinged arm 5 STYLO BS arm mounting bracket 6 Gearmotor mounting bracket 7 STYLO BS cover 8 STYLO BD cover 9 Slide guide 10 Opening stop 11 STYLO BD slide rail 12 Closing stop 13 Straight arm Main components ...

Page 7: ... of the protection circuit are fitted with additional insulation compared to the other internal conductor parts Make sure the gate structure is sturdy enough that the hinges are in proper working order and that there is no friction between the moving and fixed parts Make sure there are opening and closing mechanical stops Tools and materials Make sure you have all the tools and materials you will ...

Page 8: ...re evaluated based on actual power draw and distances When connecting products that are not specified in this manual please refer to the documen tation provided with said products Connection Type of cable Cable length 1 10 m Cable length 10 20 m Cable length 20 30 m Control panel power supply 230V FROR CEI 20 22 IEC EN 50267 2 1 3G x 1 5 mm 3G x 2 5 mm 3G x 4 mm Motor power supply 24 V DC 4G x 1 5...

Page 9: ...ation provided in this manual are subject to change at any time without prior notice EN Example of a system 1 Gearmotor unit 2 Control panel 3 Radio receiver 4 Photocells 5 External key selector 6 Flashing light 7 Antenna 8 Transmitter 9 Mechanical stop N B For reversible versions in clude the blocking electro lock ...

Page 10: ...ice Page 10 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN Examples of applications i 300 mm max with 90 opening Gate leaf opening A mm C mm D mm 90 90 0 450 90 90 180 450 90 130 180 450 120 170 0 450 Gate leaf opening A mm C mm D mm 90 90 0 400 90 90 40 400 90 90 150 400 90 90 180 400 90 90 200 400 90 230 180 300 135 230 0 300 ...

Page 11: ...cian is responsible for choosing the most suitable solution Preparation Set up corrugated tubes for the connections coming from the junction box N B the number of tubes depends on the type of system installed and any accessories Securing the brackets STYLO BS Trace all axes and dimensions respecting the levels shown in the drawing drill the marked points then secure the gearmotor anchoring bracket...

Page 12: ... 12 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN STYLO BD Trace all axes and dimensions respecting the levels shown in the drawing drill the marked points then secure the gearmotor mounting bracket to the wall or post and the slide rail Note the illustrations are mere examples it is up to the install to choose the most suitable solution depending on gate leaf type and thickness ...

Page 13: ...notice EN Drill the holes using an M8 male piece or use the M8 threaded inserts or suitable materials for securing the rail Note the illustrations are mere examples it is up to the install to choose the most suitable solution depending on gate leaf type and thickness Position the slide rail in the holes and secure it using threaded cylinder head screws ...

Page 14: ... are subject to change at any time without prior notice Page 14 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN Remove the lower cap from the gearmotor Secure the gearmotor to the flange using the four bolts supplied Secure the upper cap Securing the gearmotor ...

Page 15: ... this manual are subject to change at any time without prior notice EN STYLO BS Assemble the hinged arm by joining the two half arms with nuts and bolts Lubricate the rotation pins Insert the hinged arm onto the gearmotor shaft and secure it using the screw and washer Release the gearmotor open the gate leaf and hook the arm using the nuts and bolts Cover the hole using the cap Securing the transm...

Page 16: ...ge 16 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN STYLO BD Assemble the slide guide to the transmission arm as shown in the drawing Insert the guide into the rail Assemble the straight arm onto the gearmotor shaft Cover the hole with the cap and secure it using the supplied screws Insert the end caps of the rail and the hole covers ...

Page 17: ...ny time without prior notice EN Fully close the gate leaf and position the closing mechanical stop so that it coincides with the slide guide and then secure it Release the gearmotor see paragraph on manual release Fully open the gate leaf and position the mechanical stop so that it coincides with the slide guide and then secure it ...

Page 18: ...8 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN Open the lower cap and make the necessary electrical connections Complete installation by closing the lower cap again Cut off mains power and open the protective trap door for release Insert the key and turn it Manual release of the non reversible gearmotor Electrical connections ...

Page 19: ... vers 5 01 2015 CAME S p A The data and information provided in this manual are subject to change at any time without prior notice EN 24 V DC gearmotor with delaying closing action 24 V DC gearmotor with delaying opening action Electrical connection of the STYLO ME gearmotor to the control panel ...

Page 20: ...ided in this manual are subject to change at any time without prior notice Page 20 Manual code 119DV11EN vers 5 01 2015 CAME S p A EN 24 V DC gearmotor with delaying closing action 24 V DC gearmotor with delaying opening action Electrical connection of the STYLO RME gearmotor to the control panel ...

Page 21: ...or the key selector switch are stuck Check for power Replace the batteries Contact service Contact service Contact service The gate opens but does not close The photocells are engaged Check that the photocells are clean and work correctly Contact service The flashing light does not work The bulb has blown Contact service Troubleshooting Maintenance Periodic maintenance log to be completed by the u...

Page 22: ...stomer signature Intervention carried out _____________________________________________________________________ _______________________________________________________________________________________ ___________________________________________________________________________________ Extraordinary maintenance Installation technician stamp Operator name Date of intervention Technician signature Cust...

Page 23: ...advisable to check specific regulations in force in the place of installation DISPOSE OF PROPERLY DISPOSAL OF THE PRODUCT Our products are made with different materials Most of them aluminium plastic iron electrical cables can be disposed of together with normal household waste They can be recycled if collected sorted and sent to authorised centres Other components circuit boards remote control ba...

Page 24: ...L Voor meer informatie over het bedrijf de producten en hulp in uw eigen taal PT Para toda e qualquer informação acerca da empresa de produtos e assistência técnica em sua língua PL Wszystkie inne informacje dotyczące firmy produktów oraz usług i pomocy technicznej w Waszym języku znajdują się na stronie RU Для получения дополнительной информации о компании продукции и сервисной поддержке на вашем ...

Reviews: