background image

p. 

2

 - M

an

ua

l c

od

e: 

F

A

0

0

0

6

F

A

0006

8

-E

N

8-

E

N

 v.

 

1

 

04/2

01

5 © C

am

e S

.p.

A

. - T

he d

ata a

nd i

nfo

rm

ati

on i

n th

is

 m

an

ua

l m

ay b

e c

ha

ng

ed at a

ny ti

m

e a

nd w

ith

ou

t n

oti

ce

.

WARNING!

important safety instructions for people:

READ CAREFULLY!

Premise

• Employ this product only for the use for which it was expressly made. 
Any other use is dangerous. CAME S.p.A is not liable for any damage 
caused by improper, wrongful and unreasonable use • The safety of 
this product and its proper fi tting depends, therefore, on respecting its 
technical characteristics and proper fi tting, to be done in state-of-the-art 
fashion, and under safe conditions as expressly explained in the literature 
that comes with the product. • Keep these warnings together with the 
installation and operation manuals that come with the operator.

Before installing

(checking what's there: if something is missing, do not continue until you 
have complied with all safety provisions)

• Fitting and testing must be be only performed by qualifi ed technicians. 
Laying the cables, installation and testing mus follow state-of-the-art pro-
cedures as dictated by regulations • Before beginning any operation it 
is mandatory to carefully read all instruction; improper installation may 
result in serious harm to people and things. • Make sure the operator is 
in good mechanical state, balanced and aligned, and that it opens and 
closes properly. Also, if needed, fi t suitable protections o use proper safety 
sensors • If the operator is to be installed at a height of over 2.5 m from 
the ground or other access level, make sure you have any necessary pro-
tections and/or warnings in place • Make sure that the opening turnstile 
or gate cannot entrap people • Do not install the operator upside down 
or onto elements that could yield and bend. If necessary, add suitable 
reinforcements to the anchoring points • Do not install the operator on 
tilted surfaces • Make sure any sprinkler systems cannot wet the operator 
from the ground up.

Installing

• Suitably section off  and demarcate the entire installation site to prevent 
unauthorized persons from entering the area, especially minors and chil-
dren • Be careful when handling operators that weigh over 20 kg. If need 
be, use proper safety hoisting equipment • The CE-marked safety devices 
(photocells, stepping plates, sensitive safety-edges, emergency buttons, 
and so on), must be fi tted in compliance with the regulations in eff ect and 
according to state-of-the-art criteria, taking into account the environment, 
the type of required service and of the working forces applied to moving 
leaves. Any shearing or conveying points must be sensor-protected • Any 
residual risks must be pointed out to end users and highlighted with pic-
tograms as provided by the law. • All opening commands (that is, buttons, 
key switches, magnetic readers, and so on) must be installed at least 1.85 
m from the perimeter of the gate's working area, or where they cannot 
be reached from outside the gate. Also, any direct commands (buttons, 
touch panels, and so on) must be installed at least 1.5 m from the ground 
and must not be reachable by unauthorized persons • The turnstile must 
visibly show its identifi cation data. • Before connecting the main power 
supply make sure that the identifi cation data correspond to the those of 
the network • The turnstile must be connected to an eff ective regulation 
grounding system.
• The manufacturer declines any liability for using non-original products; 
which would result in warranty loss • All maintained action commands, 
must be fi tted in places from which the moving gate leaves and transit and 
driving areas are visible • Apply, if missing, a permanent sign showing the 
position of the release device • Before delivering to the users, make sure 
the system is EN 12453 and EN 12445 standard compliant (regarding 
impact forces), and also make sure the system has been properly adjusted 
and that any safety, protection and manual release devices are working 
properly • Apply Warning Signs where necessary and in a visible place.

Special user-instructions and recommendations

• Keep turnstile operation areas clean and free of any obstructions. Make 
sure the photocell's operating fi eld is clear of any obstructions • do not 
allow children to play with fi xed commands, or to loiter in the turnstile's 
maneuvering area. Keep any remote control transmitters or any other 
command device away from children, to prevent the operator from being 
accidentally activated • The apparatus may be used by children of eight 
years and above and by physically, mentally and perceptively challenged 
people, or even ones without any experience, provided this happens un-
der close supervision or once they have been properly instructed to use 
the apparatus safely and to the potential hazards involved. Cleaning and 
maintenance by users must not be done by children, unless properly su-

pervised • Frequently check the system for any malfunctions or signs 
of wear and tear or damage to the moving structures, to the component 
parts, all anchoring points, including cables and any accessible connec-
tions. Keep any hinges, moving joints and friction points properly lubri-
cated • Perform functional checks on the photocells and sensitive safety 
edges, every six months. Constantly clean the photocells' glass covers 
using a slightly water-moistened cloth; do not use solvents or chemicals 
that could damage the devices • If repairs or modifi cations are required 
to the system, cut off  the main power supply and do not use it until safety 
conditions have been restored • Cut off  the power supply before per-
forming any manual openings • If the power supply cable is damaged, it 
must be replaced by the manufacturer or authorized technical assistance 
service, or in any case, by similarly qualifi ed persons, to prevent any risk • 
It is FORBIDDEN for users to perform any OPERATIONS THAT ARE NOT EX-
PRESSLY REQUIRED OF THEM AND WHICH ARE NOT LISTED in the manu-
als. For any repairs, modifi cations and adjustments and for extra-ordinary 
maintenance, CALL TECHNICAL ASSISTANCE • Log the job and checks 
into the periodic maintenance log.

Further recommendations for all

• Keep away from hinges and mechanical moving parts • Do not enter 
the operator's area of operation when it is moving • Do not counter the 
operator's movement as this could result in dangerous situations • Always 
pay special attention to any dangerous points, which have to be labeled 
with specifi c pictograms and/or black and yellow stripes • When using 
a selector switch or a command in maintained actions, keep checking 
that there are no persons within the operating range of any moving parts, 
until the command is released • The gate may move at any time and 
without warning • Always cut off  the power supply before performing any 
maintenance or cleaning. 

Danger of hand crushing

Danger! High voltage.

Emergency button

Summary of Contents for SALOON40

Page 1: ...SWING LEAF TURNSTILE FA00068 EN English EN INSTALLATION MANUAL SALOON40...

Page 2: ...d to an effective regulation grounding system The manufacturer declines any liability for using non original products which would result in warranty loss All maintained action commands must be tted in...

Page 3: ...er direction can be activated by a card reader photocells or other control device The opening speed of the 90 leaf is preset The leaf opening can be automatic it closes after a preset time or activate...

Page 4: ...4 2015 Came S p A The data and information in this manual may be changed at any time and without notice Main components 1 Insulation tube 2 Inspection cover frame 3 Inspection hatch 4 Bushing covering...

Page 5: ...ensure continuity to the protection circuit are fitted with additional insulation with respect to those of other electrical parts inside Make sure the passage area is in a proper state and without any...

Page 6: ...A00068 EN 8 EN v 1 1 04 2015 Came S p A The data and information in this manual may be changed at any time and without notice Standard installation 1 Swing leaf turnstile 2 Control device 3 Barrier 4...

Page 7: ...the space available where to t the operator and accessories will vary depending on the installation site It is up to each installer to select the most suitable solution Careful Use hoisting equipment...

Page 8: ...p 8 Manual code FA0006 FA00068 EN 8 EN v 1 1 04 2015 Came S p A The data and information in this manual may be changed at any time and without notice...

Page 9: ...the anchoring base as shown in the drawing the leaf is perpendicular to the wall Mark the anchoring holes with a pencil Note when installing up against walls respect the minimum distance of 40 mm Fit...

Page 10: ...ng screws NETWORK POWER SUPPLY 230V AC Factory configuration NETWORK POWER SUPPLY 120V AC Invert cables 1 and 2 as shown Fastening the turnstile to the ground Connect the line power supply to the card...

Page 11: ...p 11 11 Manual code FA0006 FA00068 EN 8 EN v 1 1 04 2015 Came S p A The data and information in this manual may be changed at any time and without notice...

Page 12: ...A The data and information in this manual may be changed at any time and without notice At this point of the mounting use the control panel to check that the turnstile works properly the direction of...

Page 13: ...p 13 13 Manual code FA0006 FA00068 EN 8 EN v 1 1 04 2015 Came S p A The data and information in this manual may be changed at any time and without notice Center the tube with the control panel...

Page 14: ...Programming buttons 2 Programming warning LED 3 Memory roll card connector 4 R700 card connection of the first control device 5 R700 card connection of the second control device 6 Display 7 Control de...

Page 15: ...pply to the acces sories Overall allowed power 10 W Power supply 24 V AC Network power supply Transformer Clean contacts NO for connecting to warning devices Contact rated at 24 V 500 mA Terminals C N...

Page 16: ...r closing devices For details see function F 54 Contact N O of the rst SENSOR 1 control device Transponder or card reader with R700 card Contact N O of the second SENSOR 2 control device Transponder o...

Page 17: ...ramming by first performing functions A 2 Motor test and A 3 Travel calibration F 1 Total stop F 2 Setup input 2 CX F 3 Setup input 2 CY F 19 Automatic closing F 21 Preflashing F 28 Opening speed F 29...

Page 18: ...euvers calculated as a percentage Setting from 40 to 100 of the motor speed F 29 Closing speed Setting the speed during the closing maneuvers calculated as a percentage Setting from 40 to 80 of the mo...

Page 19: ...by the RBM84 access control see F 49 it is best to assign a univocal number to each one The maximum number of allowed turnstiles is 255 F 57 Offset closing limit switch See detail in the Offset closin...

Page 20: ...s are correct move on to travel calibration Motors test After pressing the leaf will perform a clockwise movement until it mechanically stops Then an inverted movement until the final mechanical stop...

Page 21: ...hout notice Offset closing limit switch Select F 57 Press ENTER to confirm Press the arrow key to compensate the limit switch closes counter clockwise Press ENTER to confirm After calibrating the trav...

Page 22: ...rd or other control device The number stays fixed for an instant to show that the user registration has been completed Select U 2 Press ENTER to confirm Select the number of the user to delete by usin...

Page 23: ...2 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136...

Page 24: ...configuring the MASTER turnstile Connect the two TOR 300 control boards with the CAT 5 U UTP AWG 24 multi pair woven unscreened cable to terminals A B GND Connect all of the necessary devices onto TOR...

Page 25: ...r until the come to a full stop The leaves will perform an inverted maneuver until the come to a full stop Transferring parameters from MASTER to SLAVE To transfer the parameters from MASTER to SLAVE...

Page 26: ...r network Check proper state of the button The turnstile stays open after a passage Automatic closing function deactivated Photocells employed Call assistance Call assistance Periodic maintenance Ever...

Page 27: ...f the fundamentals of our operating and market strategies Simply follow these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic and so on should be dispose...

Page 28: ...sson di Casier Treviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 English English Manual code FA000 FA00068...

Reviews: