Electrical connections
Power supply
LED luminous crown for warning about
the turnstile's state (see the paragraph on
"warning LED").
Warning devices
Control device
Terminals for 24 V AC
power supply to the acces-
sories.
Overall allowed power:
10 W
Power supply
24 V AC
Network power
supply
Transformer
Clean contacts (NO) for connecting to warning devices. Contact rated at: 24
V - 500 mA.
Terminals C-NO2 = open leaf warning (or contact for additional alarm.
See F-70).
Terminals C-NO1 = warns that leaf is closed.
24 V DC gearmotor with encoder
Gearmotor with encoder
TOR 300 - paired
connection.
Connection to a second
Came turnstile.
RBM84 - Access control.
Connection to Came
access control systems.
CRP - Came Remote
Protocoll.
Connection to Came home
& building automation
systems.