Function
Descripton (
negative
[
]
default values
)
F-54
Direction of entry.
Setting the direction of entry.
[ ] Commands: on 2-3 counter-clockwise opening; on 2-4 closing.
Safeties: on 2-CX and 2-CY they intervene in both rotations.
[ ] Commands: on 2-3 clockwise opening; on 2-4 closing.
Safeties: on 2-CX and 2-CY they intervene in both rotations.
[ ] Commands: on 2-3 counter-clockwise opening; on 2-4 clockwise opening.
Safeties: on 2-CX the intervene during the counter-clockwise rotation; on 2-CY they inter-
vene during the clockwise rotation.
[ ] Commands: on 2-3 clockwise opening; on 2-4 counter clockwise opening.
Safety devices: on 2-CX intervene in the clockwise rotation; on 2-CY intervene in the
counter clockwise rotation.
F-55
Standard alarm.
Setting the internal buzzer's activation time. It activates when contacts 2-CX
and 2-CY open with the leaf closed or during the pre-flashing phase set up on F-21.
[ ] To deactivate it; [ ……
] setting between 1 and 60 seconds.
F-56
Peripheral number.
If the turnstile is managed by the RBM84 access control (see F-49), it is
best to assign a univocal number to each one.
[ ……
] The maximum number of allowed turnstiles is 255.
F-57
Offset closing limit-switch.
See detail in the "Offset closing limit-switch" chapter.
From -45° [
] to no setting [ ] to +45° [
].
F-62
Automatic restoring.
Restoring time of the closing leaf, after manually forcing it.
[ ……
] Setting between 1 and 10 seconds.
F-70
Additional alarm.
It changes function to terminal C-NO2 (leaf open) for connecting a sound
alarm device.
[ ] To deactivate it; [ ] to activate it.
F-72
Change status of contacts.
It varies the (NO/NC) state of the safety contacts CX and CY. It is
for connecting any accessories with NO contacts (such as a sensitive-plate).
[
] CX becomes NO; [ ] CY becomes NO; [ ] both NO.
U-1
Memorizing a user.
See detail in the "Entering a user" chapter.
U-2
Deleting a user.
See detail in the "Deleting a user" chapter.
U-3
Completely deleting users.
Deleting all memorized users. Once deleted the following [ ] will
appear.
[ ] to delete all users.
A-2
Motor test.
See detail in the "Motor test" chapter.
[ ] To deactivate it; [ ] to activate it.
A-3
Calibrating travel.
See details in "Calibrating travel".
[ ] to deactivate it.
A-4
Reset parameters.
Deleting the entire programming
(including travel calibration) and returning to
default parameters.
[ ] to restore all default parameters.
H-1
Firmware version.
Views the firmware version. For example [
]