TOTAL STOP from button (contact 1-2)
By default, the feature is enabled.
To disable it:
select the DIP switches as shown and press the P1 key on the card. The LED blinks and the buzzer
sounds off twice.
To return to the default parameters, press P1 again. The LED stays lit and the buzzer sounds off for 1
second.
Self-learningof the gate-leaf travel
Select the DIP switches as shown and press the P1 key on the control board.
The gate will perform a series of maneuvers to determine the endstop slow-down points.
During calibration the red LED blinks. Once the calibration is complete, the buzzer sounds off for 1
second.
If the calibration has not succeeded, the LED blinks quickly and the buzzer sounds off 4 times.
You can interrupt the gate travel's self-learning operation by pressing key P1.
Input on contact 2-CX
By default,the feature is disabled.
To enable it:
Select the DIP switches as shown and press the P1 button on the control board. The LED stays on and
the buzzer sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
Reopening during closing or obstruction wait (contact 2-CX)
By default, the feature is set to reopening during closing.
To enable on obstruction wait:
select the DIP switches as shown and press the P1 button on the control board. The LED stays on and
the buzzer sounds off for one second.
To return to the default settings, press P1 again. The LED blinks and the buzzer sounds off twice.
Self-learningof the partial gate-travel
Using the control button (7) on the control board, take the gate to the desired partial opening position.
Select the DIP switches as shown and press the P1 key on the control board. The LED stays on and the
buzzer sounds off for one second.
To return to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
If the partial opening is not within the minimum and maximum limits set by default, the LED
blinks quickly and the buzzer sounds off 4 times.
OPEN-CLOSE-INVERT or OPEN-STOP-CLOSE-STOP with button (contact 2-7)
By default, the feature is OPEN-CLOSE-INVERT.
To enable it to OPEN-STOP-CLOSE-STOP:
select the DIPs as shown and press the P1 key on the on the control board. The LED stays on and the
buzzer sounds off for one second.
To return to the default settings, press P1 again. The LED blinks and the buzzer sounds off twice.
Automatic closing
By default, the feature is disabled.
To enable it:
select the DIPs as shown and press the P1 key on the control board. The LED stays on and the buzzer
sounds off for one second.
Toreturn to the default setting, press P1 again. The LED blinks and the buzzer sounds off twice.
The wait before the automatic closing starts when the opening limit-switch point is reached - for a time
that is settable on the A.C.T. trimmer.
⚠
The automatic closing does not activate if the safety devices are triggered due to obstacle detection,
after a total stop or if the power supply is missing.
Summary of Contents for OPS001
Page 2: ...3 2 1 1 2 3 4...
Page 26: ...3 2 1 1 2 3 4...
Page 50: ...3 2 1 1 2 3 4...
Page 73: ...OPS OPS001 RU FA01084 RU...
Page 74: ...3 2 1 1 2 3 4...
Page 75: ...3 FA01084 RU 02 2018 CAME S p A CAME S p A 2006 42 CE 2006 42 CE 2006 42 CE 2 5...
Page 76: ...4 FA01084 RU 02 2018 CAME S p A 3 III 1 85 1 5 2006 42 CE...
Page 81: ...3 0 0 450 40 0 50 2 UNI 5734 12 UNI 5588 M12 9 FA01084 RU 02 2018 CAME S p A 40 25 50...
Page 82: ...95 105 10 FA01084 RU 02 2018 CAME S p A 600 24...
Page 83: ...2 1 5 10 2 1 3 11 FA01084 RU 02 2018 CAME S p A 5 10...
Page 84: ...1 2 12 FA01084 RU 02 2018 CAME S p A...
Page 85: ...1 2 1 2 13 FA01084 RU 02 2018 CAME S p A...
Page 94: ...2 1 22 FA01084 RU 02 2018 CAME S p A...
Page 95: ...23 FA01084 RU 02 2018 CAME S p A CAME S p A UNI EN ISO 14001...