Programming the intercom function
Enabling/Disabling the intercom function
With VSE/301.01, please see the power supply unit documentation. Leave the function disabled on the entry
panel.
The feature is disabled by default.
+ 20’’
Press and hold the [PROG] button for approximately 20 seconds, until the
and
LEDs fl ash quickly for 3 seconds. The
[PROG] LED will fl ash quickly.
A beep confi rms set-up was successful and the [PROG] LED switches off .
In case of activation the
LED will switch off , and the
LED will stay on for a further 2 seconds.
In case of deactivation the
LED will switch off , and the
LED will stay on for a further 2 seconds.
Associating INTERCOM buttons
Do this only after associating a call button to every receiver.
< 8’’
> 11’’
Press the [PROG] button for at least 8 seconds.
Release the [PROG] button within 11 seconds.
The [PROG] LED and the
and
warning LEDs fl ash quickly.