Programming proximity cards or tags*
*LHS V/01 PLUS model only
This function is used to program proximity cards or tags, and assign one or more outputs to each to be controlled.
Do this when there are no internal receivers being associated.
Each new programmed card/tag overwrites the previous one.
①
In [Programming calls], run the proximity card or tag over the RFID reader.
②
Assign a function to the card/tag by pressing and holding the corresponding call button. Continue to press the button until
you hear a tone to confi rm.
Key
Output/Function
P1
Door release
P2
Auxiliary relay
P3
Relay 1 of actuator (e.g. VSL/2)
P4
Relay 2 of actuator (e.g. VSL/2)
Saved cards and tags can be deleted by restoring the device to factory settings. See the paragraph [Restoring