Entering programming mode
> 3’’
< 6’’
Press the [PROG] button for 3 seconds to enter programming mode.
Release the button within 6 seconds.
The warning LEDs
will fl ash together with the button LEDs.
The [PROG] LED will remain on.
If the [PROG] LED does not light up, there has been a malfunction. Check the connections and try again.
Programming the call buttons
Press [P1] to confi gure 2 x two-way buttons (max 4 calls).
Press [P2] to confi gure two single buttons (max 2 calls).
The
LED and the call button LEDs switch off .
Once [Call button programming] is complete, you are automatically taken to [Programming calls].
Programming calls
In [Programming calls] the
LED and the [PROG] LED will fl ash.
The call button LEDs will remain on.
From here you can continue with further programming.
When reprogramming a system, you start from this step. You do not need to program the call buttons again.
To repeat [Programming call buttons] see the paragraph on [Reprogramming a system].