Cable types and minimum thicknesses
CABLE LENGTH (m)
< 10
from 10 to 20
from 20 to 30
230 V AC Power supply
3G x 1.5 mm²
3G x 1.5 mm²
3G x 2.5 mm²
-|24v-- 24 V AC - DC Flashing light|-
2 x 1 mm²
2 x 1 mm²
2 x 1 mm²
TX Photocells
2 x 0.5 mm²
2 x 0.5 mm²
2 x 0.5 mm²
RX photocells
4 x 0.5 mm²
4 x 0.5 mm²
4 x 0.5 mm²
Command and control devices
*n° x 0.5 mm²
*n° x 0.5 mm²
*n° x 0.5 mm²
Antenna
RG58 max 10 m
*no. = see product mounting instructions - Warning: the cable section is merely indicative as it depends on the motor power and cable length.
For installation in an outdoor environment, use cables with properties equivalent to at least those of type H05RN-F (with designation 60245 IEC 57).
For installation in an indoor environment, use cables with properties equivalent to at least those of type H05VV-F (designation to 60227 IEC 53).
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected devices and
according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. For connecting products that are not contemplated in this manual, see the literature accompanying said products
For combined connection and CRP, use a UTP CAT5-type cable. Maximum length 1000 metres.
Wind resistance
Type
Boom 3.05 m
Boom 4.05 m
Resistance class
4
3
Wind pressure [Pa]
1000
800
Maximum wind speed [km/h]
132
118