p.
21
- Manual
FA01313-EN
- 02/2019 - © C
AME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Connecting the magnetic loop to the SMA module *
L3 L4 L5 L6
* Only for GPX40MGP
Function of the outputs of the RS485 I/O board *
1
Contact output indicating obstacle detection indication
2
Contact output indicating open boom
3
Contact output indicating closed boom
4
Contact output indicating boom drop-away
5
Open inspection hatch signal contact output
6
Released gearmotor signal contact output
7
CX input status signal contact output
8
Input for the connection of a button with OPEN ONLY function
(COM-N1)
9
Input for the connection of a button with CLOSE ONLY function
(COM-N2)
Each output is a clean contact (NO) with maximum
capacity 1A – 24 V DC.
N1 N2
24 0
A B GND
N3 N4 COM N5 N6 N7 N8 COM
1
8
9
2
3
4
5
6
7