Travel sensitivity
Adjusting the obstruction detection sensitivity during boom travel.
Configuration >
Gate travel settings
Travel sensitivity
from 10% to 100% (Default) - 10% = maximum sensitivity - 100% = minimum
sensitivity
RSE1
Configures the function to be performed by the board connected to the RSE1 connector.
Configuration >
RSE communication
RSE1
RSE1
Combined
Bushing
Disabled
Saving data
It saves user data, timings and configurations to the memory device (memory roll or USB key).
The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.
Configuration >
External memory
Saving data
Confirm? NO (Default)
Confirm? YES
Data reading
It uploads user data, timings and configurations from the memory device (memory roll or USB key).
The function is displayed only when a USB memory stick is inserted into the USB port or when a memory roll is inserted into the control board.
External memory
Data reading
Confirm? NO (Default)
Confirm? YES
Opening direction
Set the boom opening direction.
Configuration
Motor settings
Guided procedure (Wizard)
Opening direction
To the left (Default)
To the right
CRP address
It assigns a unique identification code (CRP address) to the control board. The function is necessary if there are more operators connected by CRP.
Configuration >
RSE communication
CRP address
Set up maintenance
For setting the number of partial maneuvers (in thousands) that the automation can perform, before a signal is generated that warns of the need to perform
maintenance. The signal consists of the 3 + 3 times rhythmic flashing of the warning light [Open every hour].
Information
Set up maintenance
Deactivated (Default)
from 1 to 1000 (1 = 1000 maneuvers)
RSE1 speed
Sets the remote connection system communication speed on the RSE1 port.
Configuration
RSE communication
RSE1 speed
4800 bps
9600 bps
14400 bps
19200 bps
38400 bps (Default)
57600 bps
115200 bps