p.
36
- Manual
FA01313-EN
- 02/2019 - © C
AME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
ERROR MESSAGES
Calibration error
Interruption of the boom travel calibration due to the presence of an obstruction.
The Encoder does
not work
The Encoder is disconnected.
The Encoder is broken.
Services test failure
error
Presence of an obstruction within the range of the photocells.
The photocells are not correctly connected or configured.
The photocells are faulty.
Work time expired
Finished the maximum work time set.
Hatch open
The operator is released.
Maximum number of
closing obstructions
Exceeded the maximum number of obstacles consecutively detected
Maximum number of
opening obstructions
Exceeded the maximum number of obstacles consecutively detected
Maximum number
of obstructions
Exceeded the maximum number of obstacles consecutively detected
Serial
communication
error
Configured on the wrong RSE port.
Incompatible remote
control
The transmitter used is not CAME.
The coding set is different from that of the transmitter.
The transmitters are TWIN and have different KEY BLOCK.
Slave door open
The SLAVE operator is released.
Detached boom
The boom was pushed-open.
Incorrect ARM contact wiring.
Boom not present detection sensor.
Released motor
The boom has been released by the gearmotor and it can be moved manually.
Open gearmotor safety microswitch contact.