Send the PARTIAL/PEDESTRIAN OPENING command
(contact 2-3P) from a transmitter or other control
device, to open the boom on the SLAVE barrier.
.
Approach the MASTER barrier, which will automatically
open only after the SLAVE barrier automatically closes
.
Send the STEP-STEP (contact 2-7) command from a
transmitter or other control device, to simultaneously
open the booms of the MASTER and SLAVE barrier.
Send the ONLY OPEN command (contact 2-3) from a
transmitter or other control device, to open the boom
of the MASTER barrier.
.
Approach the SLAVE barrier. It will automatically open
only after the MASTER barrier automatically closes.
.
ALTERNATE FUNCTION
Important! Start by doing the following on both barriers:
- Fit the RSE card into the connector on the control panel of both operators.
- connect the two control panels via a CAT 5 type-cable (max 1,000 m) to terminals A-A / B-B / GND-GND, see paragraph on CONNECTING
FOR PAIRED OR ALTERNATE OPERATING MODE.
Connect the safety and control device with ONLY OPEN function (contact 2-3) and STEP-STEP function (contact 2-7) on the MASTER control
panel.
Connect the safety and control devices with PARTIAL / PEDESTRIAN OPENING function (contact 2-3P) only on the SLAVE control panel.
Important! Activate function F 19 (automatic closing time) on the control panel of both operators.
Memorizing
Perform the enter-user procedure with the ONLY OPEN, and STEP-STEP command on the MASTER control panel while the
PARTIAL / PEDESTRIAN OPENING function is to be performed on the SLAVE control board.
Confi guring the MASTER operator
Select function F 49. Press ENTER to confi rm.
Select 2 (alternate) and press ENTER.
Transferring parameters from MASTER to SLAVE
Select function F 52 on the MASTER control panel.
Select 1 and press ENTER.
Programming
On both barriers, set the following functions:
- setting the boom type (A1);
- motor test (A2)
- total stop (F1);
- travel calibration (A3).
Carry out any settings and adjustments on the MASTER control panel.
Operating modes
ONLY OPEN (contact 2-3) command. For opening MASTER barrier boom.
PARTIAL/PEDESTRIAN OPENING (contact 2-3P) command. For opening the SLAVE barrier boom.
STEP-STEP (contact 2-7) command. Both booms open. This is an emergency opening command, to free the passage.
For the types of command that can be selected and paired to users, see the ENTERING USERS WITH ASSOCIATED COMMANDS