SAFETY DEVICES
Photocells
Configure contact CX or CY (NC), safety input for photocells.
See function ofInput CX (function F2) or CY (function F3) in:
C1 reopening while closing. When the barrier is closing, opening the contact causes its movement to invert until fully opened;
C4 obstruction wait. Theleaf stops if moving and starts moving again once the obstruction is removed;
C5 immediate closing. Closing the barrier after a vehicle has passed through the operating area of the safety devices; C9 immediate
closing with obstruction wait when closing. Closing the barrier after a vehicle has passed through the operating area of the safety
devices;
C9 immediate closing with obstruction wait when closing. Closing the boom after a vehicle has passed through the operating area of
the safety devices.
If unused, contacts CX and CY should be deactivated during programming.
Photocells (safety test)
At each opening and closing command, the control board checks the efficacy of the safety devices (such as, photocells).
Any malfunction inhibits any command and the display will show the Er4 wording.
Enable function F5 in programming.