background image

 5

 1

 2

 4

 9

10

11

 6

 3

 7

 8

P.

 1

2

1

2

  - M

a

n

u

a

l c

o

d

1

1

9

G

V

6

5

11

9

G

V

6

5

 v

e

r.

 2

.1

2

.1

  0

2

/2

0

11 © C

A

M

E

 C

a

n

ce

lli A

u

to

m

a

ti

ci

 S

.p.

a

. - T

h

e d

a

ta a

n

d i

n

fo

rm

ati

o

n i

n

 t

h

is

 m

a

n

u

a

l m

ay b

e c

h

a

n

g

e

d at a

n

y time a

n

d wit

h

o

u

t o

b

lig

a

ti

o

n

 o

n

 t

h

e p

a

rt

 of C

a

me C

a

n

ce

lli A

u

to

m

a

ti

ci

 S

.p.

a

. to n

o

tif

y s

a

id

 c

h

a

n

g

e

s.

ENGLISH

Description of the control panel

Technical data

Designed and built by CAME Cancelli Automatici S.p.A. The control 
panel is powered by 120 / 230 V AC, at 50 / 60 Hz frequency.
The command devices and accessories are powered by 24V. War-
ning! The accessories must not exceed 40 W overall.
The control panel features an amperometric device whih constantly 
controls the motor thrust data.  
 When the barrier arm runs into an obstacle, this is detected by the 
encoder which acts accordingly on the movement :
 - when opening: the arm inverts the direction of travel until it is 
fully closed;
- when closing: the arm inverts the direction of travel until it is fully 
open; this triggers the automatic closing. 
Warning! Afterthree consecutive inversions, the arm stays raised 
up and automatic closing is excluded: to close press the command 
button or transmitter key.

All connections are protected by quick fuses, see table.
The card handles the following functions:
- automatic closing after an opening command;

F U S E   TA B L E

to protect:

fuses for:

120 V Electronic card (line)

5 A-F

230 V Electronic card (line)

3.15 A-F

24 V Accessories

2 A-F

Command devices (control panel)

1 A-F

Motor

15 A-F

T E C H N I C A L   D ATA

power source

120/230 V - 50/60 Hz

max power

400 W

power draw when idle

110 mA

maximum power for 24 V accessories

40 W

circuit insulation class

II

container material

ABS

container protection rating

IP54

working temperature

-20 / +55°C

- immediate closing;
- Prefl ashing by the fl ashing light;
- obstacle detection with arm stopped at any point.

Types of command:
- opening/closing;
-opening/closing with maintained action;
- opening;
- total stop.

Optional accessories:
Flashing-light domeand luninous cord;
fl ashing light for open barrier arm: it turns off  when barrier ar is 
closed;

        

Warning! Before acting on the control panel, cut off the 

power supply.

1 -  Fusibile motore
2 -  Accessories fuse
3 -  Control panel fuse
4 -  Transformer terminals
5 -  Radiofrequency card connector
6 -  Programming buttons

7 -  LED warning light to signal lack of calibration or open thermal 

contact

8 -  Power supply LED-signal light
9 -  Motor terminals
10 -  Accessories terminals
11 -  Display

Main component parts

Summary of Contents for G3000

Page 1: ...G3000 G3000I SERIES GARD INSTALLATION MANUAL QUICK ROAD BARRIERS English EN...

Page 2: ...l release of the barrier arm p 11 Description of the control panel p 12 Technical data p 12 Main component parts p 12 Electrical connections p 13 Gearmotor encoder and transformer only for possible ma...

Page 3: ...ible to the public All maintained action com mands must be placed where the moving gate leaves transit areas and driveways are completely visible If missing ap ply a permanent label that shows the pos...

Page 4: ...d reflective adhesive strips 001G03002 60 mm white varnished aluminium tube arm L 3 m complete with red reflective adhesive bands 001G02040 40 mm balancing spring for the 001G03002 barrier 001G04060 5...

Page 5: ...eflective adhesive strips 2 Semi eliptical arm attachment flange complete with flange cover and arm end caps 3 60 mm tube arm attachment flange complete with flange cover and arm end caps 4 40 Balanci...

Page 6: ...ctric cable raceways making sure these are protected from any mechanical damage Set up a drainage tube to prevent stagnation of moisture that can lead to oxydation Check that any connections inside th...

Page 7: ...same line i e sequential ones the dimensions shown on the table must be reconsidered according to the total draw and actual distances When connecting products not featured in this manual only refer t...

Page 8: ...must be perfectly level clean and with the bolt threading completely on the surface Wait at least 24 hrs for everything to solidify Remove the nuts and washers from the threaded screws The following...

Page 9: ...g mounting phase the barrier may be unstable Do not rest against barrier until fully mounted to avoid any tumbling over LEFT hand barrier RIGHT hand barrier Installing the cabinet NOTE This manual sho...

Page 10: ...se the inspection hatch and power up the system Activate the arm to check whether it is parallel to the road surface when close and at about 89 when open To correct the vertical position opening lower...

Page 11: ...s broken or cracked during an accident etc the tension springs no longer provide balan ce This may result in sudden rotating movements of arm attachment and or of the arm itself Insert the key into th...

Page 12: ...nd button or transmitter key All connections are protected by quick fuses see table The card handles the following functions automatic closing after an opening command FUSE TABLE to protect fuses for...

Page 13: ...Terminals for powering accessories 24 A 230 V AC Overall allowed power 40 W Power source and accessories Power supply 230 V AC Frequency 50 60 Hz N B remove the protection which is fastened with one...

Page 14: ...in case of Maintai ned Action Flashing light for open barrier arm Contact rated for 24 V 3 W Max Warns that the barrier arm is open See function settings on F 10 Flashing light dome and luminous cord...

Page 15: ...the test on Electrical connection to work the photocells safety test Safety devices Con gure the CX or CY contact N C which is an input for EN 12978 regulation compliant safety devices such as photoc...

Page 16: ...NTER button pressed for at least a full second Use the arrows to choose the menu item you wish then press ENTER use the arrows also the move in the sub menus Use the arrows to increase or decrease the...

Page 17: ...sitivity during movement F 35 Sensitivity during deceleration F 37 Adjusting the opening deceleration beginning point of the M1 motor F 38 Adjusting the closing deceleration beginning point of the M1...

Page 18: ...the buttons or transmitter to resume movement Insert safety device on 1 C2 if unused select function 0 0 0 Deactivated 1 Activated by default F 2 CX input NC safety contact with ppssobility to associ...

Page 19: ...p close stop modes 0 step step by default 1 sequential F 9 Obstacle detection when motor is idle the arm is down up or after a total stop command it prevent movement if the safety davices i e photocel...

Page 20: ...fore the arm begins to travel the pre flashing time can be deactivated or adjusted from 1 to 10 0 Deactivated by default 1 1 second 2 2 seconds 10 10 seconds F 22 Working time working time of the moto...

Page 21: ...percentage of the arm s complete travel 40 40 of the arm travel 50 50 of the arm travel by default 70 70 of the arm travel F 38 Motor closing deceleration point adjusts the motor s beginning point of...

Page 22: ...iated command adding user max 25 users associated to a command via tramsitter 1 1 step command open close 2 2 sequential commande open stop close stop 3 open only command U 2 Cancelling user cancellin...

Page 23: ...e arrow buttons to select the command 1 step 2 sequential 3 open to assign to the user Press ENTER to confirm Adding user with associated command 3 an available number between 1 and 25 will flash for...

Page 24: ...1 CAME Cancelli Automatici S p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes ENGLISH...

Page 25: ...perly and that motor runs properly Er3 encoder out of order call for assistance Er4 services test error check proper connections and functioning state of the safety devices Er5 insufficient working ti...

Page 26: ...ger high voltage Transit forbidden during operation Important general safety instructions The periodic maintenance actionsto be done by the end users are cleaning the photocells glass checking the pro...

Page 27: ...____________________________________________________________________________________________ _______________________________________________________________________________________________ Extraordina...

Page 28: ...be handed over the specially authorised disposal firms Before proceeding it is always a good idea to check your local legislation on the matter DO NOT DISPOSE OF IN NATURE Troubleshooting Dismantling...

Page 29: ...5 ver 2 1 2 1 02 2011 CAME Cancelli Automatici S p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify s...

Page 30: ...Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 122n...

Reviews: