Approach the MASTER barrier which will
open automatically only after the SLAVE
barrier has closed automatically.
Send a STEP-BY-STEP command (contact
2-7) from the transmitter or other control
device to open the MASTER and SLAVE
barrier booms at the same time.
Approach the SLAVE barrier which will open
automatically only after the MASTER barrier
has closed automatically.
ALTERNATE CONNECTION
Important! First do the following on both operators:
- insert the RSE card (with the dipswitches set to OFF) on the panel connector on both operators.
- connect the two boards with a CAT 5 cable (max. 1,000 m) to terminals A- / B-B / GND-GND; see CONNECTION FOR PAIRED or ALTERNATE
OPERATION)
Connect the safety and control devices with the OPEN function (contact
2-3
) and STEP-BY-STEP (contact
2-7
) on the panel on the MASTER operator.
Connect the safety and control devices with the PARTIAL/PEDESTRIAN OPENING function (contact
2-3P
) on the panel of the SLAVE operator only.
Important! Activate the F 19 function (automatic closing time) on the panel on both operators.
Saving
Follow the procedure for entering a user with the OPEN and STEP-BY-STEP command on the MASTER panel and the PARTIAL/PEDESTRIAN OPENING
on the SLAVE panel.
Confi guring the MASTER operator
Select function F 49. Press ENTER to confi rm.
Select 2 (alternate) and press ENTER.
Parameter transfer from MASTER to SLAVE
Select function F 52 on the MASTER panel.
Select 1 and press ENTER.
Programming
Set the following functions on both barriers:
- motor type (A1);
- motor test (A2);
- total stop (F1);
- travel calibration (A3).
Proceed with setting and adjusting the MASTER panel.
Function modes
OPEN command (contact 2-3). To open the MASTER barrier boom.
PARTIAL/PEDESTRIAN OPENING command (contact 2-3P). To open the SLAVE barrier boom.
STEP-BY-STEP command (contact 2-7). Both booms open. This is an emergency opening command to free up the passage.
For information on the types of command that can be selected and associated with users, see the section ENTERING USERS WITH AN
ASSOCIATED COMMAND.
Send an OPEN command (contact 2-3)
from the transmitter or other control device
to open the MASTER barrier boom.
Send a PARTIAL/PEDESTRIAN OPENING
command (contact 2-3P) from the
transmitter or other control device to open
the SLAVE barrier boom.
Summary of Contents for G2080E
Page 33: ...Automatic barriers GARD 8 series G2080E G2080IE INSTALLATION AND OPERATION English FA01030 EN...
Page 65: ...Barri res automatiques s rie GARD 8 G2080E G2080IE MANUEL D INSTALLATION Fran ais FA01030 FR...
Page 97: ...GARD 8 G2080E G2080IE FA01030 RU...
Page 98: ...2 FA01030 RU 1 01 2018 CAME S p A CAME S P A 2 5 20 1 8 1 5 EN12453 EN12445 8...
Page 103: ...7 FA01030 RU 1 01 2018 CAME S p A 24 600...
Page 104: ...N M 8 FA01030 RU 1 01 2018 CAME S p A 90 M N...
Page 105: ...UNI5931 M8x20 UNI5931 M8x12 UNI5931 M8x20 UNI6954 2 9x13 9 FA01030 RU 1 01 2018 CAME S p A...
Page 107: ...11 FA01030 RU 1 01 2018 CAME S p A 45 UNI5739 M12x70 UNI5588 M12...
Page 113: ...1 8 9 1 8 9 17 FA01030 RU 1 01 2018 CAME S p A 89...
Page 121: ...10 11 1 E 10 11 1 E 4 Z L 3 8 25 FA01030 RU 1 01 2018 CAME S p A...
Page 125: ...29 FA01030 RU 1 01 2018 CAME S p A 6...
Page 127: ...31 FA01030 RU 1 01 2018 CAME S p A CAME S p A UNI EN ISO 14001...