Functions mapping
F 1
Total stop function (1-2)
F 2
Function associated with CX input
F 3
Function associated with CY input
F 5
Safety test function
F 6
Hold-to-run function
F 9
Obstruction detection function with motor idle
F 10
Indicator light function
F 11
Exclude encoder
F 14
Sensor type selection function
F 15
Luminous cord intermittence function
F 18
Additional light function
F 19
Automatic closing time
F 21
Pre-flashing time
F 22
Working time
F 25
Courtesy light time
F 28
Opening speed adjustment
F 29
Closing speed adjustment
F 30
Opening slow-down speed adjustment
F 31
Closing slow-down speed adjustment
F 33
Calibration speed adjustment
F 34
Sensitivity during movement
F 35
Sensitivity during slow-down
F 37
Adjustment of opening slow-down starting point
F 38
Adjustment of closing slow-down starting point
F 49
Activation of serial connection
F 50
Save data to the memory roll
F 51
Read data on the memory roll
F 52
Parameter transfer from Master to Slave
F 60
Sleep mode
F 61
Pre-flashing function
U 1
Type of command to associate with user using radio control
U 2
Delete a single user
U 3
Delete all users
A 1
Set boom type
A 2
Motor test
A 3
Travel calibration
A 4
Parameter reset
A 5
Count number of manoeuvres
H 1
Software version
Functions menu
F1
Total stop [1-2]
0 = Deactivated (
default
) / 1 = Activated
N.C. Input – Stop boom while excluding automatic closing; to resume movement, use the command device. The safety device should be
inserted in [1-2].
F2 Input
[2-CX]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC Input – Possible associations: C1 = reopening during closing by photocells, C4 = obstacle stand-by, C5 = immediate closure, C9 = im-
mediate closure with obstacle stand-by during closing.
F3 Input
[2-CY]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC Input – Possible associations: C1 = reopening during closing by photocells, C4 = obstacle stand-by, C5 = immediate closure, C9 = im-
mediate closure with obstacle stand-by during closing.
IMPORTANT! Start programming these functions first: SET BOOM TYPE (A1), MOTOR TEST (A2), TOTAL STOP (F1) AND TRAVEL
CALIBRATION (A3).
Summary of Contents for G2080E
Page 33: ...Automatic barriers GARD 8 series G2080E G2080IE INSTALLATION AND OPERATION English FA01030 EN...
Page 65: ...Barri res automatiques s rie GARD 8 G2080E G2080IE MANUEL D INSTALLATION Fran ais FA01030 FR...
Page 97: ...GARD 8 G2080E G2080IE FA01030 RU...
Page 98: ...2 FA01030 RU 1 01 2018 CAME S p A CAME S P A 2 5 20 1 8 1 5 EN12453 EN12445 8...
Page 103: ...7 FA01030 RU 1 01 2018 CAME S p A 24 600...
Page 104: ...N M 8 FA01030 RU 1 01 2018 CAME S p A 90 M N...
Page 105: ...UNI5931 M8x20 UNI5931 M8x12 UNI5931 M8x20 UNI6954 2 9x13 9 FA01030 RU 1 01 2018 CAME S p A...
Page 107: ...11 FA01030 RU 1 01 2018 CAME S p A 45 UNI5739 M12x70 UNI5588 M12...
Page 113: ...1 8 9 1 8 9 17 FA01030 RU 1 01 2018 CAME S p A 89...
Page 121: ...10 11 1 E 10 11 1 E 4 Z L 3 8 25 FA01030 RU 1 01 2018 CAME S p A...
Page 125: ...29 FA01030 RU 1 01 2018 CAME S p A 6...
Page 127: ...31 FA01030 RU 1 01 2018 CAME S p A CAME S p A UNI EN ISO 14001...