background image

Pa

g.

 

2

  - M

an

u

al

 c

od

e: 

11

9

D

U

3

2

E

N

11

9

D

U

3

2

E

N

 ve

r.

 

2

  

2  

0

1/

2

0

14  © C

A

M

E S

.p.

A

. - T

h

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is

 in

sta

lla

tio

n m

an

u

al

 a

re s

u

sc

ep

tib

le to c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n C

A

M

E S

.p.

A

. to n

otify u

se

rs.

ENGLISH

Premise

• Employ this product only for the use for which it was expressly made. Any 
other use is dangerous. CAME S.p.A. is not liable for any damage caused by 
improper, wrongful and unreasonable use • Keep these warnings together 
with the installation and operation manuals that come with the operator. 

Before installing

(checking what's there: if your evaluation is negative, do not proceed befo-
re having complied with all safety requirements) 

• Check that the automated parts are in good mechanical order, that the 
operator is level and aligned, and that it opens and closes properly. Make 
sure you have suitable mechanical stops • If the operator is to be installed 
at a height of over 2.5 m from the ground or other access level, make sure 
you have any necessary protections and/or warnings in place • If any pe-
destrian openings are fi tted into the operator, there must also be a a system 
to block their opening while they are moving • Make sure that the opening 
automated door or gate cannot entrap people against the fi xed parts of 
the operator • Do not install the operator upside down or onto elements 
that could yield and bend. If necessary, add suitable reinforcements to the 
anchoring points • Do not install door or gate leaves on tilted surfaces • 
Make sure any sprinkler systems cannot wet the operator from the ground 
up • Make sure the temperature range shown on the product literature is 
suitable to the climate where it will be installed • Follow all instructions as 
improper installation may result in serious bodily injury • It is important to 
follow these instructions for the safety of people. Keep these instructions. 

Installing

• Suitably section off  and demarcate the entire installation site to pre-
vent unauthorized persons from entering the area, especially minors and 
children • Be careful when handling operators that weigh over 20 kg. If 
need be, use proper safety hoisting equipment • All opening commands 
(that is, buttons, key switches, magnetic readers, and so on)  must be 
installed at least 1.85 m from the perimeter of the gate's working area, 
or where they cannot be reached from outside the gate. Also, any direct 
commands (buttons, touch panels, and so on) must be installed at least 
1.5 m from the ground and must not be reachable by unauthorized persons 
• All maintained action commands, must be fi tted in places from which 
the moving gate leaves and transit and driving areas are visible • Apply, 
if missing, a permanent sign showing the position of the release device • 
Before delivering to the users, make sure the system is EN 12453 standard 
compliant (regarding impact forces), and also make sure the system has 
been properly adjusted and that any safety, protection and manual release 
devices are working properly • Apply Warning Signs (such as the gate's 
plate) where necessary and in a visible place 

Special user-instructions and recommendations 

• Keep gate operation areas clean and free of any obstructions. Make 
sure that the photocells are free of any overgrown vegetation and that 
the operator's area of operation is free of any obstructions • Do not allow 
children to play with fi xed commands, or to loiter in the gate's maneuve-
ring area. Keep any remote control transmitters or any other command 
device away from children, to prevent the operator from being accidentally 
activated. • The apparatus may be used by children of eight years and 
above and by physically, mentally and sensorially challenged people, or 
even ones without any experience, provided this happens under close su-
pervision or once they have been properly instructed to use the apparatus 
safely and about the potential hazards involved. Children must not play 
with the apparatus. Cleaning and maintenance by users must not be done 
by children, unless properly supervised • Frequently check the system 
for any malfunctions or signs of wear and tear or damage to the moving 
structures, to the component parts, all anchoring points, including cables 
and any accessible connections. Keep any hinges, moving joints and slide 
rails properly lubricated • Perform functional checks on the photocells and 
sensitive safety edges, every six months. To check whether the photocells 
are working, wave an object in front of them while the gate is closing; if 
the operator inverts its direction of travel or suddenly stops, the photocells 
are working properly. This is the only maintenance operation to do with the 
power on. Constantly clean the photocells' glass covers using a slightly 
water-moistened cloth; do not use any solvents or other chemical products 
that may ruin the devices • If repairs or modifi cations are required to the 
system, release the operator and do not use it until safety conditions have 
been restored • Cut off  the power supply before releasing the operator for 
manual openings and before any other operation, to prevent potentially 
hazardous situations. Read the instructions • If the power supply cable is 
damaged, it must be replaced by the manufacturer or authorized technical 
assistance service, or in any case, by similarly qualifi ed persons, to prevent 
any risk • It is FORBIDDEN for users to perform any OPERATIONS THAT ARE 

NOT EXPRESSLY REQUIRED OF THEM AND WHICH ARE NOT LISTED in the 
manuals. For any repairs, modifi cations and adjustments and for extraordi-
nary maintenance, CALL TECHNICAL ASSISTANCE • Log the job and checks 
into the periodic maintenance log. 

Additional special recommendations for everyone 

• Keep away from hinges and mechanical moving parts • Do not enter 
the operator's area of operation when it is moving • Do not counter the 
operator's movement as this could result in dangerous situations • Always 
pay special attention to any dangerous points, which have to be labeled 
with specifi c pictograms and/or black and yellow stripes • While using a 
selector switch or a command in maintained actions, keep checking that 
there are no persons within the operating range of any moving parts, until 
the command is released • The gate may move at any time and without 
warning • Always cut off  the power supply before performing any mainte-
nance or cleaning.

Danger of hand crushing 

Danger! High voltage. 

No transiting while maneuvering 

WARNING! 

important safety instructions for people:

READ CAREFULLY! 

Danger of foot crushing 

Summary of Contents for FERNI 1024 KIT

Page 1: ...INSTALLATION MANUAL F1024 AUTOMATION FOR SWING GATES English EN 119DU32EN...

Page 2: ...ree of any obstructions Make sure that the photocells are free of any overgrown vegetation and that the operator s area of operation is free of any obstructions Do not allow children to play with xed...

Page 3: ...is symbol tells you that the sections concern safety issues This symbol tells you what to say to the end users 2 Intended use and restrictions The FERNI 24V operator is speci cally engineered to autom...

Page 4: ...there is a soundly secured to the ground mechanical stop to prevent the gate leaf gearmotor from over extending You may perform internal back up circuit connections provided you use additional insula...

Page 5: ...l panel power supply FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 24 V motor power supply 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 Flashing light 2 x 1 5 mm2 2 x 1 5 mm2 2 x 1...

Page 6: ...S p A to notify users ENGLISH 5 5 Mounting Secure the base plate to the pillar using 8 screws and 14 moulded inserts making sure the minimum distance of 150mm from the ground is met Secure the A brack...

Page 7: ...to notify users ENGLISH Fig 2 Insert the straight semi arm into the motor shaft Apply the ared washer the M6x20 screw and lock the semi arm using the two grub screws Join and secure the two arms using...

Page 8: ...n the cam Closing release the gearmotor and lead the gate leaf 500 mm from the fully closed position Turn the lower cam until the microswitch is inserted and tighten the screw found on the cam Lower c...

Page 9: ...y obstructions We suggest checking the state of lubrication and tightness of the anchoring screws on the operator To check the efficiency of the safety devices move an object in front of the photocell...

Page 10: ...released The transmitter s batteries are run down The transmitter is broken The stop button is either stuck or broken The opening closing button or the keyswitch are stuck Check that the power is up...

Page 11: ...d and compliant environmental protection system at its plants to ensure that environmental safeguarding We ask you to keep protecting the environment as CAME deems it to be one of the fundamental poin...

Page 12: ...English EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N CONTROL PANEL FOR 24V GEARMOTORS 319U33EN...

Page 13: ...the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features an amperometric device whih c...

Page 14: ...ABS container protection rating IP54 working temperature 20 55 C You can also connect gate open warning lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outa...

Page 15: ...ation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Preliminary checks Tr...

Page 16: ...ecure the base of the panel in a safe area yes max 6 mm Head with to 5 3 Anchoring and installing the box Perforate the marked holes and insert the cable glands with corrugated tubes for the electrica...

Page 17: ...e changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections brown brown blue 2 FROG 24 V motors 1 FROG 24 V motor 2 FERNI...

Page 18: ...60 Hz frequency Accessories power source Lighting and warning devices Gate open warning light Contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Flashing light co...

Page 19: ...r safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully openend If...

Page 20: ...ECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10 6 1 Electrical connection for photocells functionalities test Stop b...

Page 21: ...2 1 2 3 4 ON 5 6 7 8 9 10 CH1 CH2 RA2 RC2 C FA1 FC1 C FA2 FC2 C RA1 RC1 C TERMICO 3P 7 C1 C3 1 2 3 ENGLISH P 10 10 Manual code 319U33 319U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The dat...

Page 22: ...djusted to between 2 and 120 seconds DELAY 2M Adjusting the M2 waiting time for each closing The waiting time can be adjusted to between 1 and 15 seconds Warning minimum sensitivity maximum power Afte...

Page 23: ...M 433 92 AF43TW TWIN KeyBlock AM 433 92 AF43SR ATOMO AM 40 685 AF40 TOUCH AM 863 35 AF868 TOP 9 Activating the radio command Connect the antenna cable to the terminals Antenna Radio frequency card Pos...

Page 24: ...U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify...

Page 25: ...ED ashes ON and OFF 2 Press the button on the transmitter to be memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 26: ...id waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially auth...

Reviews: