 Keep CH1 button pressed on the electronic card. The LED fl ashes ON and OFF.

2)

 Press the button on the transmitter to be memorised. The LED will stay ON to confi rm memorisation is OK.

Flashing LED

LED on

CH1

 

=  Channel for direct function command to gearmotor control panel ("open only" command / "open-close-invert" command o 

"open-stop-close-stop", depending on selection made on DIP switches 2 and 3).

CH2

 

=  Channel for direct commands to an accessory device connected on B1-B2.

3)

Repeat the procedure for point

1

and 

2

 for button

 

“CH2” associating it with the other transmitter button.

 

Memorisation

Summary of Contents for FERNI 1024 KIT

Page 1: ...INSTALLATION MANUAL F1024 AUTOMATION FOR SWING GATES English EN 119DU32EN...

Page 2: ...ree of any obstructions Make sure that the photocells are free of any overgrown vegetation and that the operator s area of operation is free of any obstructions Do not allow children to play with xed...

Page 3: ...is symbol tells you that the sections concern safety issues This symbol tells you what to say to the end users 2 Intended use and restrictions The FERNI 24V operator is speci cally engineered to autom...

Page 4: ...there is a soundly secured to the ground mechanical stop to prevent the gate leaf gearmotor from over extending You may perform internal back up circuit connections provided you use additional insula...

Page 5: ...l panel power supply FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 1 5 mm2 3G x 2 5 mm2 24 V motor power supply 2G x 1 5 mm2 2G x 1 5 mm2 2G x 2 5 mm2 Flashing light 2 x 1 5 mm2 2 x 1 5 mm2 2 x 1...

Page 6: ...S p A to notify users ENGLISH 5 5 Mounting Secure the base plate to the pillar using 8 screws and 14 moulded inserts making sure the minimum distance of 150mm from the ground is met Secure the A brack...

Page 7: ...to notify users ENGLISH Fig 2 Insert the straight semi arm into the motor shaft Apply the ared washer the M6x20 screw and lock the semi arm using the two grub screws Join and secure the two arms using...

Page 8: ...n the cam Closing release the gearmotor and lead the gate leaf 500 mm from the fully closed position Turn the lower cam until the microswitch is inserted and tighten the screw found on the cam Lower c...

Page 9: ...y obstructions We suggest checking the state of lubrication and tightness of the anchoring screws on the operator To check the efficiency of the safety devices move an object in front of the photocell...

Page 10: ...released The transmitter s batteries are run down The transmitter is broken The stop button is either stuck or broken The opening closing button or the keyswitch are stuck Check that the power is up...

Page 11: ...d and compliant environmental protection system at its plants to ensure that environmental safeguarding We ask you to keep protecting the environment as CAME deems it to be one of the fundamental poin...

Page 12: ...English EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N CONTROL PANEL FOR 24V GEARMOTORS 319U33EN...

Page 13: ...the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features an amperometric device whih c...

Page 14: ...ABS container protection rating IP54 working temperature 20 55 C You can also connect gate open warning lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outa...

Page 15: ...ation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Preliminary checks Tr...

Page 16: ...ecure the base of the panel in a safe area yes max 6 mm Head with to 5 3 Anchoring and installing the box Perforate the marked holes and insert the cable glands with corrugated tubes for the electrica...

Page 17: ...e changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections brown brown blue 2 FROG 24 V motors 1 FROG 24 V motor 2 FERNI...

Page 18: ...60 Hz frequency Accessories power source Lighting and warning devices Gate open warning light Contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Flashing light co...

Page 19: ...r safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully openend If...

Page 20: ...ECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10 6 1 Electrical connection for photocells functionalities test Stop b...

Page 21: ...2 1 2 3 4 ON 5 6 7 8 9 10 CH1 CH2 RA2 RC2 C FA1 FC1 C FA2 FC2 C RA1 RC1 C TERMICO 3P 7 C1 C3 1 2 3 ENGLISH P 10 10 Manual code 319U33 319U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The dat...

Page 22: ...djusted to between 2 and 120 seconds DELAY 2M Adjusting the M2 waiting time for each closing The waiting time can be adjusted to between 1 and 15 seconds Warning minimum sensitivity maximum power Afte...

Page 23: ...M 433 92 AF43TW TWIN KeyBlock AM 433 92 AF43SR ATOMO AM 40 685 AF40 TOUCH AM 863 35 AF868 TOP 9 Activating the radio command Connect the antenna cable to the terminals Antenna Radio frequency card Pos...

Page 24: ...U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify...

Page 25: ...ED ashes ON and OFF 2 Press the button on the transmitter to be memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 26: ...id waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially auth...

Reviews: