ELECTRICAL CONNECTIONS
Passing the electrical cables
Connect all wires and cables in compliance with the law.
The electrical cables must not touch any parts that may overheat during use (such as the motor and transformer).
Use membrane cable glands to connect the devices to the control panel. One of these must be intended exclusively for the power supply cable.
Thread the cables through the holes in the control board holder (
A
). The cables need to sit perfectly flush to the side of the operator as shown below to
ensure the cover closes. Use cable ties or insulating tape if necessary.
Power supply
Make sure the mains power supply is disconnected during all installation procedures.
Before working on the control panel, disconnect the mains power supply and remove the batteries, if any.
Connecting to the mains (230 V AC - 50/60 Hz)
F
Line fuse
L
Phase
N
Neutral
Earth
L
N
F
Power supply output for accessories
The output normally delivers 24 V AC.
10 11 E1 5
E1
5