P
age
28
- Manual
FA01795-EN
- 03/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CX input, CY input, CZ input, CK input
Associate a function with the input CX CY CZ CK
Configuration >
Wired safety devices
CX input
CY input
CZ input
CK input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate stop once the obstruction has been
removed, even if the gate is not in motion
r7 = Reopen while closing (sensitive edges with 8K2 resistor)
r8 = Reclose while opening (sensitive edges with 8K2 resistor)
r7 (two sensitive edges) = Reopen while closing (pair of sensitive edges with 8K2
resistor)
r8 (two sensitive edges) = Reclose while opening (pair of sensitive edges with 8K2
resistor)
Safety devices test
Check that the photocells connected to the selected inputs are operating correctly, after each opening and closing command.
Run the test by connecting the photocells to the TS terminal [see paragraph on Safety devices].
Configuration >
Wired safety devices
Safety devices test
Deactivated (Default)
CX _ _ _
_ CY _ _
CX CY _ _
_ _ CZ _
CX _ CZ _
_ CY CZ _
CX CY CZ _
_ _ _ CK
CX _ _ CK
_ CY _ CK
CX CY _ CK
_ _ CZ CK
CX _ CZ CK
_ CY CZ CK
CX CY CZ CK
Obstacle with motor stopped
With the function active, the operator remains stopped if the safety devices detect an obstacle. The function is active when the gate is closed, open or after a
complete stop.
Configuration >
Wired safety devices
Obst. with motor stopped
Disabled (Default)
On
RIO ED T1 and RIO ED T2
Associate one of the available functions with a wireless safety device.
The function only appears if the RIO CONN interface board is present.
Configuration >
RIO safety devices
RIO ED T1
RIO ED T2
Deactivated (Default)
P0 = It stops the gate and excludes automatic closing. Use a control device to resume
movement.
P7 = Reopen while closing.
P8 = Reclose while opening.