FASTENING THE OPERATOR
Once the adjustments are complete, fasten the operator to the plate using the supplied hardware.
Spring
For closing:
- close the gate;
- fi t the closing limit-switch tab into the rack until the micro-switch is activated (spring) and fasten it using the grub screws.
ESTABLISHING THE LIMIT-SWITCH POINTS
For opening:
- open the gate;
- fi t the opening limit-switch tab onto the rack until the micro switch activates (spring) and fasten it using the grub screws.