DETAILS ON INSTRUMENT FUNCTIONS
CANC:
this function enables the user to simultaneously delete ALL tests stored in the internal instrument memory. To activate,
n
press the
right
button for 2 seconds; the text flashes on display to indicate that the unit is awaiting confirmation; to confirm
deletion, press the
right
button again for 2 seconds
Aur: (Average)
is the function that enables a calculation of the mathematical average of the four parameters memorised on
n
any three tests. (see details on page
5
)
SEND:
this function enables the user to send all memorised tests directly from the instrument to the computer, via a USB cable
n
or Bluetooth with the special adaptor for PC, simultaneously clearing the internal memory. To send tests to the PC, first connect
the instrument to the computer using the USB cable (or connect the special Bluetooth adaptor), start the BlueForce program,
and press the
right
button for 2 seconds. The message "SEND" flashes on display for the entire duration of the test transfer
phase.
REMARK:
In the case of transmission error
(Err 2)
, the saved tests will not be lost, and so it will be possible to retry to send the
n
tests, by press again the
right
button for 2 seconds.
PC ON:
this function enables the user to switch from the "display off" phase and activate direct delivery of data to the computer
n
(via USB cable or via Bluetooth with the special adaptor for PC). To enter the PCON mode, press the
right
button for 2 seconds.;
the text
PC ON
flashes on display; press the
right
button again for 2 seconds (see details on page
5
).
dAtE:
current date, in the format DD/MM/YY. To see the current date, press the
right
button for 2 seconds and then to change
n
the date, press the
right
button again for 2 seconds and
briefly press the right button
to change the day/month/year as
required. To change the number, briefly press the
left
button or press and hold the latter to change the direction of modification
(increase/decrease); after this, press and hold the
right
button to save the changes and exit.
Hour:
current hour/minutes, in the format HH.MM. To see the current time, press the
right
button for 2 seconds and then to
n
change the hour, press the
right
button again for 2 seconds and
briefly press the right
button to change the day/month/year
as required. To change the number, briefly press the
left
button or press and hold the latter to change the direction of
modification (increase/decrease); after this, press and hold the
right
button to save the changes and exit.
NOTE:
Date and time setting is only available for models with internal clock (not Upgrade).
n
CAL:
date of last calibration, in the format DD/MM/YY. Press the
right
button for 2 seconds to display.
n
n
PASS:
input of the code to enable the NFC and Bluetooth interfaces (if not enabled). Go to the
PASS
function, then press the
right button for 2 sec
. to entry in the “ insert code” mode, the first figure of the code flashes. Briefly press the
left
button to
increase the first number 1->2->3 ecc. To go to the next figure briefly press the
right
button then repeat this operation for all
the four numbers. At the end, to confirm the code and quit,
press the right button for 2 sec
., if the code is correct, the display
will show the writing “YES”
FUNC SPECIAL MENU:
When scrolling through the memorised tests, users can select the
FUNC
special menu, present between the first
n
and last tests. This menu contains several functions:
CANC
,
Aur
,
SENd
,
PCON
,
dAtE
,
Hour
,
CAL
,
PASS
(the last one is present only if the
bluetooth and NFC functions are disabled, see next section for detai
To access the "sub-functions" move to
FUNC,
then briefly press the
right
button to "rotate" the "sub-functions»
n
MORE DISPLAY MESSAGGES
BATTERY CHECK:
If battery charge is low, the display shows
bAtt
until any key is pressed. Anyway it will be possible to carry
n
out at least another complete test, before replacing (see details on page
18
).
CALIBRATION:
This alert appears a month before the calibration due date; if more than one year (Calibration validity period)
n
has passed, it will appear whenever the device is switched on. The alert disappears after a few seconds
MEMORY TEST:
If the device has used up all the memory locations available, the display shows
FULL
until any key is pressed.
n
If you proceed without
erase
or
download
saved tests, the instrument overwrites
always
the test n°1.
ERROR CHECK:
if it occurs any internal errors, the display shows
Err1
or
Err2
etc. until any key is pressed
n
N.B.
WITH BLUEFORCE SOFTWARE: verify the setting of the serial port (see page
11
) and check that either the USB CABLE, the
n
Bluetooth DEVICE, is inserted in the USB port correctly.