13
Blue Force Software - details
Selection of the type of gate.
n
The evaluation of test result, is carried out based on current selection of type of gate (sliding door, hinged door, tilting door, barrier, etc.) and
n
on current measuring point.
Therefore, this selection determines the validity (or not) of the result shown by Gauge.
n
By means of the corresponding curtain-menu, it is possible to select the kind of gate more suitable for the gate to verify.
n
To every kind of gate, there are pre-defined all the measuring position, indicated by norms, plus a generic point at limit 400N and another
n
point at limit 1400N.
Based on the selected gate and the positions, the program shows a picture that indicates the point of measure. The following kinds of gate
n
are available:
1
-Folding door,
2
-Hinged door,
3
-Sliding door,
4
-Lifting door,
5
-Barrier,
6
-Tilting door,
7
-Single household tilting
n
door,
8
-Pedestrian folding door,
9
-Pedestrian hinged door,
10
-Pedestrian rotating door,
11
-Pedestrian sliding door,
12
-Single household lifting door
PRINT REPORT
To print out the report of the tests associated with a
door
(as required by EN
n
12453), proceed as follows: create the
door
type, enter all the door's
characteristics, transfer the tests carried out (at the points listed by the
software), and then, finally,
select the door
. You can now view a print
preview (to check that all the data entered is correct), then proceed with the
printout.
Remark: The report can be printed in the PDF format in which it is drawn up.
n
N.B. The result of the measurements is reprocessed automatically by the software when the tests
are copied or moved from the
test lists
to a new door created in the
test management
section.
VIEWING AND PRINTING OVERLAID GRAPHS
To print out several overlaid graphs (from 2 to a maximum of 5),
n
proceed as follows:
Left-click
the mouse to select the desired graphs
n
Right-click
once to view the whole graph and then
again
to
n
enable the print function.
PRINT TEST LIST
It is possible to generate a print report of all tests present in section "tests list".
n
In the report section "Tests data", are reported only measures Dynamic Force, dynamic Time, Static Force, Final (End) Force, of all tests
n
saved.
The report sections Verifier Data, Customer Data and gate Identification, are left empty to permit to technician to write them, after printing
n
report.
INSTRUMENT / LANGUAGE SETTING
The language setting can be accessed from the
File, Settings menu.
n
In the menu
File, Settings, Info
: the main specifications of the
n
instrument are displayed: Model, Serial number, Calibration date,
firmware version, (Date and Time settings are only found on models
equipped with internal clock).