background image

ATI: 

TYPICAL GATE SETUP

     

4

1

2

5

3

OUTSIDE OF GATES

INSIDE OF GATES

7

8

6

1

ATI Motor

4

Flashing Light (optional)

7

2nd set of Photocells (optional)

2

Control Panel

5

Selector Keypad (optional)

8

Mechanical End Stop (not supplied)

3

Reception Antenna

6

Photocells (on outside of gate posts)

9

Photocell column (optional accessory)

CONTROL PANEL

PHOTOCELLS

•  The control panel should be mounted in an accessible position and not directly behind the gates, to avoid a 

potential crushing hazard.

•  Use cable glands to connect the devices to the control panel. One of these must be used exclusively for the 

power supply cable.

•  All holes should be sealed to avoid ingression and maintain the IP54 protection rating.

 

Only a competent service provider should open the enclosure 

 

and adjust the settings.

•  The photocells are used in pairs, one transmitter and one receiver.

•  They should be installed between 500-600mm from the ground, facing each other.

•  Power for the photocells is taken from the control panel 24v AC.

•  The maximum range of the photocell should always be observed.

When the photocell beam is broken, the control panel can be programmed on how to react. 

Please see ‘Safety’ section for more information.

Summary of Contents for ATI-P3

Page 1: ...UP GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a pair of swing gates with leaves up to 3m wide TO BE READ IN CONJUNCTION...

Page 2: ...0A Motor x2 ATI P3 KIT CONTENTS x2 topd4Fks Fixed code Transmitter 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Pan...

Page 3: ...sing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate m...

Page 4: ...lands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection ratin...

Page 5: ...ction between the fixed and moving parts 2 Make sure that measurement C does not exceed the value shown in the reference table 3 Make sure that you have fitted opening and closing mechanical gate stop...

Page 6: ...the power supply as instructed by your installer even in a power cut Release any additional locking device fitted to the gate eg electric lock etc 1 Raise the door covering the lock A 2 Insert the key...

Page 7: ...T 0 12 24 L2T 2 FC1 FA2 FC2 FA1 L2T L1T 1 2 3 4 0 12 24 ZA3P Control Panel 10 2 TX C NC TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m AF43S Plug in TOP A433N...

Page 8: ...etween terminal 1 2 3 If no safety device has been connected to the C1 terminal then disable the safety input C1 Permanent link wire between terminal 2 C1 4 Disable safety input CX Dip switch 8 on 5 S...

Page 9: ...The PROG LED goes solid to signal the successful saving of the code 3 Release the CH1 key A maximum of 25 individual buttons can be saved remove all transmitters 1 Press and hold the CH1 and CH2 butto...

Page 10: ...ty circuit is triggered the automation will stop and reverse its motion until it reaches its fully closed position again Once the automation has reached the fully closed position it will require anoth...

Page 11: ...r 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue backlighti...

Page 12: ...HIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm...

Reviews: