7 Selecting functions

1 ON - 

Automatic closing - The automatic closing timer activates at the closing endpoint. The pre-set time is adjustable, but it's in any 
case subject to any safety device intervention and does not activate after a total "stop" or in case of power failure.

2 OFF - 

"Open-stop-close-stop" function with (2-7) button and transmitter.

2 ON - 

"Open-close" function with (2-7) function and transmitter.

3 ON - 

"Open only" function with transmitter.

4 ON - 

Opening and closing prefl ashing  - After either an opening or closing command, the fl ashing light connected on 10-E, fl ashes 
for 5 seconds before beginning to execute the command.

5 ON - 

Obstacle detection - With motor idle (door-leaf closed, open or after a total stop command), it prevents any movement if the 
safety devices (e.g. photocells) detect an obstacle.

6 ON - 

Maintained action - Door opens and closes only if button is kept pressed.

7 ON - 

Ramming function activated - At each opening command, the door presses against the strike plate for one second, facilitating 
the release operation for the electro lock connected on terminals 11-S.

8 OFF - 

Partial stop - Door stops is in movement which consequently triggers automatic closing, insert the safety device on terminal 
(2-C3);if unused, set DIP switch to ON.

9 OFF - 

Total stop - This function stops the door and then excludes any automatic closing cycle; use either the buttons or transmitter to 
resume movement. Insert safety device on [1-C2]; if unused, set DIP switch to ON.

10 OFF -   Reopening during closing - The photocells, detect an obstacle during the closing phase of the door leaf, triggering an inversion 

of travel direction, until door is fully open; Insert the safety device on terminal (2-C1); if unused, set DIP switch to ON.

1 - Must stay OFF 

2 - Must stay OFF

3 ON - Activates the safety tests to check photocell effi

  ciency.   

4 - Unused

10-WAY DIP-SWITCH

4-WAY DIP-SWITCH

DIP

POS

.

F

UNCTION

 

ACTIVATED

Summary of Contents for 319U36EN

Page 1: ...English EN INSTALLATION MANUAL ZL19NA Z CONTROL PANELS CONTROL PANEL FOR 24V GEARMOTORS 836EN...

Page 2: ...30 V AC at 50 60 Hz frequency the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features...

Page 3: ...ntainer protection rating IP54 working temperature 20 55 C You can also connect the open door signal lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outages...

Page 4: ...ed with extra insulation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Pr...

Page 5: ...1 Secure the base of the panel in a safe area yes max 6 mm Head with to 2 Perforate where shown and insert the gable gland with the corrugated tubes for the electrical cables to go through Careful no...

Page 6: ...automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections...

Page 7: ...ssories power source Lighting and warning devices Flashing light for open doorContact rated for 24 V 3 W Max Signals the position of the open door it turns off when the door is closed Flashing light c...

Page 8: ...ls and other devices that comply with EN 12978 regulations Door stopping if it is moving with subsequent automatic closing If unused set DIP switch n 8 to ON Safety devices C1 N C contact di riapertur...

Page 9: ...to activate the test IMPORTANT When you activate the safety test CHECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10...

Page 10: ...ommand it prevents any movement if the safety devices e g photocells detect an obstacle 6 ON Maintained action Door opens and closes only if button is kept pressed 7 ON Ramming function activated At e...

Page 11: ...ADJ SENS End adjustement of amperometric sensor during travel min max AMP SENS Adusts the amperometric sensitivity which controls the force developed by the motor during movement if the force exceeds...

Page 12: ...nges Adjusting the microswitch Swing the door until it is about 500 mm from its closed position Turn the outer cam until the micro switch is inserted and lock it using the screw Micro switch Outer slo...

Page 13: ...radio command Connect antenna cable to the apposite terminals Antenna Possible second channel output of the radio receiver N O contact Contact rated for 1 A 24 V DC Jumper p 4 point 15 in pos B Adjust...

Page 14: ...teries and snap in the radio frequency card into the electronic card N B The electronic card recognises the radio frequency card only when it is powered up Only for the AF43S AF43SM radi frequency car...

Page 15: ...132 T134 T138 T152 T154 T158 ATOMO AT01 AT02 AT04 TWIN TWIN 2 TWIN 4 ENGLISH P 15 15 Manual code 319U36 319U36 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manua...

Page 16: ...ashes ON and OFF 2 Press the button on the transmitter you want memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 17: ...solid waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially a...

Page 18: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Reviews: