background image

2! 2# #

2! 2# #

&! &#

# &! &# #

M2

M1  N1  M2  N2

R

A

1

M1  N1  M2  N2

R    

RC   

F

A

     F     

M     

N

2! 2# #

2! 2# #

&! &#

# &! &# #

R    

RC   

F

A

     F     

M     

N

M1

M2

ENGLISH

P.

 

66

 - 

M

an

u

al

 c

od

e: 

31

9

U

3

6

31

9

U

3

6

 ve

r.

 

1.

0

1.

0

 05

/2

0

11

 © C

A

M

E c

an

ce

lli auto

m

ati

ci

 s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on

 in

 th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny tim

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n th

e p

art of C

am

e C

an

ce

lli A

uto

m

ati

ci

 S

.p.a. to n

otify s

ai

d c

h

an

g

es.

6 Electrical connections

2 EMEGA 24 V motors

1 EMEGA 24 V motor

Power supply 

Power supply 

Opening 

limit switch 

Closing 

slowdown

Opening 
limit switch 

Closing 
slowdown

Shortcircuit 

Summary of Contents for 319U36EN

Page 1: ...English EN INSTALLATION MANUAL ZL19NA Z CONTROL PANELS CONTROL PANEL FOR 24V GEARMOTORS 836EN...

Page 2: ...30 V AC at 50 60 Hz frequency the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features...

Page 3: ...ntainer protection rating IP54 working temperature 20 55 C You can also connect the open door signal lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outages...

Page 4: ...ed with extra insulation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Pr...

Page 5: ...1 Secure the base of the panel in a safe area yes max 6 mm Head with to 2 Perforate where shown and insert the gable gland with the corrugated tubes for the electrical cables to go through Careful no...

Page 6: ...automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections...

Page 7: ...ssories power source Lighting and warning devices Flashing light for open doorContact rated for 24 V 3 W Max Signals the position of the open door it turns off when the door is closed Flashing light c...

Page 8: ...ls and other devices that comply with EN 12978 regulations Door stopping if it is moving with subsequent automatic closing If unused set DIP switch n 8 to ON Safety devices C1 N C contact di riapertur...

Page 9: ...to activate the test IMPORTANT When you activate the safety test CHECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10...

Page 10: ...ommand it prevents any movement if the safety devices e g photocells detect an obstacle 6 ON Maintained action Door opens and closes only if button is kept pressed 7 ON Ramming function activated At e...

Page 11: ...ADJ SENS End adjustement of amperometric sensor during travel min max AMP SENS Adusts the amperometric sensitivity which controls the force developed by the motor during movement if the force exceeds...

Page 12: ...nges Adjusting the microswitch Swing the door until it is about 500 mm from its closed position Turn the outer cam until the micro switch is inserted and lock it using the screw Micro switch Outer slo...

Page 13: ...radio command Connect antenna cable to the apposite terminals Antenna Possible second channel output of the radio receiver N O contact Contact rated for 1 A 24 V DC Jumper p 4 point 15 in pos B Adjust...

Page 14: ...teries and snap in the radio frequency card into the electronic card N B The electronic card recognises the radio frequency card only when it is powered up Only for the AF43S AF43SM radi frequency car...

Page 15: ...132 T134 T138 T152 T154 T158 ATOMO AT01 AT02 AT04 TWIN TWIN 2 TWIN 4 ENGLISH P 15 15 Manual code 319U36 319U36 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manua...

Page 16: ...ashes ON and OFF 2 Press the button on the transmitter you want memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 17: ...solid waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially a...

Page 18: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Reviews: