background image

CAME

CAME 

 France

France 

 S.a.  

S.a.  

FRANCE

7, Rue Des Haras

Z.i. Des Hautes Patures

92737 Nanterre Cedex

Nanterre Cedex

 (+33) 0 825 825 874

 (+33) 1 46 13 05 00

GERMANY 

CAME Gmbh Seefeld

 

CAME Gmbh Seefeld

Akazienstrasse, 9

16356  Seefeld 

Seefeld Bei Berlin

 (+49) 33 3988390

 (+49) 33 39883985

CAME Automatismes S.a. 

CAME Automatismes S.a. 

FRANCE

3, Rue Odette Jasse

13015 Marseille

Marseille

 (+33) 0 825 825 874

 (+33) 4 91 60 69 05

U.A.E. 

CAME Gulf Fze

 

CAME Gulf Fze

Offi ce No: S10122a2o210

P.O. Box 262853 

Jebel Ali Free Zone - Dubai 

Dubai 

 (+971) 4 8860046

 (+971) 4 8860048

CAME Automatismos S.a. 

CAME Automatismos S.a. 

SPAIN

C/juan De Mariana, N. 17-local

28045 Madrid

 Madrid

 (+34) 91 52 85 009

 (+34) 91 46 85 442

RUSSIA CAME 

Rus

 CAME 

Rus

Umc Rus Llc

Umc Rus Llc

Ul. Otradnaya D. 2b, Str. 2, offi ce 219 

127273, Moscow

Moscow 

 (+7) 495 739 00 69

 (+7) 495 739 00 69 (ext. 226)

CAME United Kingdom Ltd. 

CAME United Kingdom Ltd. 

GREAT BRITAIN

Unit 3 Orchard Business Park

Town Street, Sandiacre

Nottingham 

Nottingham - Ng10  5bp

 (+44) 115 9210430

 (+44) 115 9210431

PORTUGAL CAME 

Portugal 

 CAME 

Portugal 

Ucj Portugal Unipessoal Lda

Ucj Portugal Unipessoal Lda

R

ua Liebig, nº 23 

2830-141 Barreiro

Barreiro  

 (+351) 21 207 39 67

 (+351) 21 207 39 65

CAME Group Benelux S.a. 

CAME Group Benelux S.a. 

BELGIUM

Zoning Ouest 7

7860 Lessines

 Lessines

 (+32) 68 333014

 (+32) 68 338019

INDIA CAME 

India 

 CAME 

India 

Automation Solutions Pvt. Ltd

Automation Solutions Pvt. Ltd

A - 10, Green Park 

110016 - New Delhi

New Delhi  

 (+91) 11 64640255/256

 (+91) 2678 3510

CAME Americas Automation Llc 

CAME Americas Automation Llc 

U.S.A

11345 NW 122nd St. 

Medley

Medley, FL 33178 

 (+1) 305 433 3307

 (+1) 305 396 3331

ASIA CAME 

Asia 

Pacific 

 CAME 

Asia 

Pacific 

60 Alexandra Terrace #09-09

B

lock C, The ComTech

118 502 Singapore

Singapore  

 (+65) 6275 8426

 (+65) 6275 5451

CAME Gmbh 

CAME Gmbh 

GERMANY

Kornwestheimer Str. 37

70825 Korntal 

 Korntal Munchingen Bei Stuttgart 

 (+49) 71 5037830

 (+49) 71 50378383

CAME Cancelli Automatici S.p.a. 

CAME Cancelli Automatici S.p.a. 

ITALY

Via Martiri Della Libertà, 15

31030 Dosson Di Casier 

 Dosson Di Casier (Tv)

 (+39) 0422 4940 

 (+39) 0422 4941

Informazioni Commerciali 800 848095

ITALY 

CAME Sud s.r.l.

CAME Sud s.r.l.

Via F. Imparato, 198

Centro Mercato 2, Lotto A/7 

80146 Napoli

 Napoli

 (+39) 081 7524455

 (+39) 081 7529190

CAME Service Italia S.r.l. 

CAME Service Italia S.r.l. 

ITALY

Via Della Pace, 28

31030 Dosson Di Casier 

 Dosson Di Casier (Tv)

 (+39) 0422 383532 

 (+39) 0422 490044

Assistenza Tecnica 800 295830

Assistenza Tecnica 800 295830

ITALY 

CAME Global Utilities s.r.l.

CAME Global Utilities s.r.l.

V

ia E. Fermi, 31

20060 Gessate

Gessate

 (Mi)

 (+39) 02 95380366

 (+39) 02 95380224

01_2011

www.came.com

www.came.it

En

g

li

sh

En

g

li

sh

 - M

an

u

al

 c

od

31

9

U

3

6

31

9

U

3

6

 ver

1.

0

1.

0

 05

/2

0

11

 © C

A

M

E c

an

ce

lli a

u

to

m

at

ic

i s

.p.

a.

 

T

h

e d

at

a a

n

d i

n

fo

rm

at

io

n i

n t

h

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed a

t a

n

y t

im

e a

n

d w

it

h

ou

t o

b

lig

at

io

n o

n t

h

e p

ar

t o

f C

am

e C

an

ce

lli A

u

to

m

at

ic

i S

.p.

a.

 t

o n

ot

if

y s

ai

d c

h

an

g

es

.

Summary of Contents for 319U36EN

Page 1: ...English EN INSTALLATION MANUAL ZL19NA Z CONTROL PANELS CONTROL PANEL FOR 24V GEARMOTORS 836EN...

Page 2: ...30 V AC at 50 60 Hz frequency the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features...

Page 3: ...ntainer protection rating IP54 working temperature 20 55 C You can also connect the open door signal lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outages...

Page 4: ...ed with extra insulation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Pr...

Page 5: ...1 Secure the base of the panel in a safe area yes max 6 mm Head with to 2 Perforate where shown and insert the gable gland with the corrugated tubes for the electrical cables to go through Careful no...

Page 6: ...automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections...

Page 7: ...ssories power source Lighting and warning devices Flashing light for open doorContact rated for 24 V 3 W Max Signals the position of the open door it turns off when the door is closed Flashing light c...

Page 8: ...ls and other devices that comply with EN 12978 regulations Door stopping if it is moving with subsequent automatic closing If unused set DIP switch n 8 to ON Safety devices C1 N C contact di riapertur...

Page 9: ...to activate the test IMPORTANT When you activate the safety test CHECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10...

Page 10: ...ommand it prevents any movement if the safety devices e g photocells detect an obstacle 6 ON Maintained action Door opens and closes only if button is kept pressed 7 ON Ramming function activated At e...

Page 11: ...ADJ SENS End adjustement of amperometric sensor during travel min max AMP SENS Adusts the amperometric sensitivity which controls the force developed by the motor during movement if the force exceeds...

Page 12: ...nges Adjusting the microswitch Swing the door until it is about 500 mm from its closed position Turn the outer cam until the micro switch is inserted and lock it using the screw Micro switch Outer slo...

Page 13: ...radio command Connect antenna cable to the apposite terminals Antenna Possible second channel output of the radio receiver N O contact Contact rated for 1 A 24 V DC Jumper p 4 point 15 in pos B Adjust...

Page 14: ...teries and snap in the radio frequency card into the electronic card N B The electronic card recognises the radio frequency card only when it is powered up Only for the AF43S AF43SM radi frequency car...

Page 15: ...132 T134 T138 T152 T154 T158 ATOMO AT01 AT02 AT04 TWIN TWIN 2 TWIN 4 ENGLISH P 15 15 Manual code 319U36 319U36 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manua...

Page 16: ...ashes ON and OFF 2 Press the button on the transmitter you want memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Page 17: ...solid waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially a...

Page 18: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Reviews: