Partial opening or pedestrian opening (contact 2-3P)
By default, the opening is set to pedestrian mode.
To enable in partial opening:
Select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Obstruction detection with motor stopped
By default, the feature is enabled.
To disable it:
Select the DIP-switches as shown and press the PROG button on the control board. The LED flashes and the
buzzer sounds off twice.
To return to the default setting, press PROG again. The LED stays on and the buzzer sounds off for one
second.
Excluding the Encoder
By default, the Encoder is enabled.
The enable the exclusion:
select the DIP-switches as shown and press the PROG key on the board. The LED flashes and the buzzer
sounds of once.
To return to the default setting, press PROG again. The LED stays lit and the buzzer sounds off twice.
Timed slow-downs (with Encoder disabled)
By default, this function is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Set the OP TIME trimmer to its maximum setting, the SENS trimmer to half, and save the trimmer value.
Automatic closing
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. The LED stays on and
the buzzer sounds for one second.
Toreturn to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
The wait before the automatic closing starts when the opening limit-switch point is reached - for a time that
is settable on the A.C.T. trimmer.
⚠
The automatic closing does not activate if the safety devices are triggered due to obstacle detection, after
a total stop or if the power supply is missing.
Automatic closing after either partial or pedestrian opening
By default, the feature is disabled.
To enable it:
Select the DIP-switches as shown and press the PROG button on the control board. THE PRG LED stays lit
and the buzzer sounds off for one second.
To return to the default setting, press the PROG button again. The LED flashes and the buzzer sounds off
twice.
⚠
The automatic closing time is permanently set to 10 seconds.
Pre-flashing (pre-flashing duration: 5 s)
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. THE PRG LED stays lit
and the buzzer sounds off for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Closing thrust
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG button on the control board. THE PRG LED stays lit
and the buzzer sounds off for one second.
To return to the default setting, press PROG again. The LED flashes and the buzzer sounds off twice.
Summary of Contents for 002ZL60
Page 17: ...EN English FA01040 EN CONTROL PANEL FOR 24 V GEARMOTORS ZL60 INSTALLATION MANUAL...
Page 33: ...FR Fran ais FA01040 FR ARMOIRE DE COMMANDE POUR MOTOR DUCTEURS 24 V ZL60 MANUEL D INSTALLATION...
Page 49: ...RU FA01040 RU 24 ZL60...
Page 50: ...2 FA01040 RU 02 2018 CAME S p A 2006 42 CE 2006 42 CE CAME S p A 1 5...
Page 51: ...3 FA01040 RU 02 2018 CAME S p A III...
Page 63: ...15 FA01040 RU 02 2018 CAME S p A PROG 5 PROG 7 5 PROG 5...