Timed slow-downs with Encoder disabled
Set the OP TIME trimmer to maximum, set the SENS
trimmer to half, save the trimmers' values, disable the
Encoder, enable the timed slow-down function.
- Perform a self-learning run of the leaf travel.
The operator will perform a series of maneuvers to establish
the starting slow-down and limit-switch points.
= 25% of the operating time at slowed down speed
when opening.
= 25% of the operating time at slowed down speed when
closing.
Resetting the opening and closing slow-down starting points
- Close the gate leaves.
- Perform a self-learning run of the leaf swing arc. When M2
reaches the closing slow-down starting point, during an
opening maneuver
B
(10/45 %), press the PROG button.
- Again press the PROG button when M2 reaches the
opening slow-down starting point, during the same
maneuver
A
(55/90 %).
Repeat the procedure for M1.
Auto-learning of the gate-leaf travel
With the Encoder enabled (the default setting)
- Select the Dip-switch and press the PROG button the control board as explained in the functions
programming section.
The operator will perform a series of maneuvers to establish
the starting slow-down and limit-switch points.
= 25% of the movement area at slowed down speed
when opening.
= 25% of the movement area at slowed down speed
when closing.
With Encoders and timed slow-downs disabled
If the Encoder and Slow-down functions are both
disabled, the gate leaves will open or close completely at a
constant, limited speed of 50% of the top speed.
Summary of Contents for 002ZL60
Page 17: ...EN English FA01040 EN CONTROL PANEL FOR 24 V GEARMOTORS ZL60 INSTALLATION MANUAL...
Page 33: ...FR Fran ais FA01040 FR ARMOIRE DE COMMANDE POUR MOTOR DUCTEURS 24 V ZL60 MANUEL D INSTALLATION...
Page 49: ...RU FA01040 RU 24 ZL60...
Page 50: ...2 FA01040 RU 02 2018 CAME S p A 2006 42 CE 2006 42 CE CAME S p A 1 5...
Page 51: ...3 FA01040 RU 02 2018 CAME S p A III...
Page 63: ...15 FA01040 RU 02 2018 CAME S p A PROG 5 PROG 7 5 PROG 5...